ArticleNuclear medicine and biology2016
Radiosynthesis of clinical doses of ⁶⁸Ga-DOTATATE (GalioMedix™) and validation of organic-matrix-based ⁶⁸Ge/⁶⁸Ga generators.
Article in Nuclear medicine and biology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 33 citations in OpenAlex.
- Automated Synthesis of Radiopharmaceuticals: Technology, Applications, and Regulatory Perspectives.Nuclear medicine and molecular imaging · 2026Review
- Increasing the activity output and optimization of automated radiosynthesis [EJNMMI radiopharmacy and chemistry · 2026Article
- Influences of Ring Sizes and Chiral Substituents on Macrocyclic Chelators for ImprovingJACS Au · 2026Article
- In Vivo Evaluation ofPharmaceutics · 2024Article
- A personal acquisition time regimen ofCancer imaging : the official publication of the International Cancer Imaging Society · 2022Article
- Automated synthesis of [EJNMMI radiopharmacy and chemistry · 2022Article
- 3p-C-NETA: A versatile and effective chelator for development of AlTheranostics · 2022Article
- Peptide-BasedMolecular pharmaceutics · 2018Article
- Preliminary PET/CT Imaging with Somatostatin Analogs [Molecular imaging and biology · 2017Article
- Development of aACS omega · 2017Article
- Installation and Optimization ofIndian journal of nuclear medicine : IJNM : the official journal of the Society of Nuclear Medicine, IndiaArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
Abstract
introduction68Ga-DOTATATE is a radiolabeled peptide-based agonist that targets somatostatin receptors overexpressed in neuroendocrine tumors. Here, we present our results on validation of organic matrix 68Ge/68Ga generators (ITG GmbH) applied for radiosynthesis of the clinical doses of 68Ga-DOTATATE (GalioMedixTM).
methodsThe clinical grade of DOTATATE (25 μg±5 μg) compounded in 1 M NaOAc at pH=5.5 was labeled manually with 514±218 MBq (13.89±5.9 mCi) of 68Ga eluate in 0.05 N HCl at 95°C for 10 min. The radiochemical purity of the final dose was validated using radio-TLC. The quality control of clinical doses included tests of their osmolarity, endotoxin level, radionuclide identity, filter integrity, pH, sterility and 68Ge breakthrough.
resultsThe final dose of 272±126 MBq (7.35±3.4 mCi) of 68Ga-DOTATATE was produced with a radiochemical yield (RCY) of 99%±1%. The total time required for completion of radiolabeling and quality control averaged approximately 35 min. This resulted in delivery of 50%±7% of 68Ga-DOTATATE at the time of calibration (not decay corrected).
conclusions68Ga eluted from the generator was directly applied for labeling of DOTA-peptide with no additional pre-concentration or pre-purification of isotope. The low acidity of 68Ga eluate allows for facile synthesis of clinical doses with radiochemical and radionuclide purity higher than 98% and average activity of 272±126 MBq (7.3±3 mCi). There is no need for post-labeling C18 Sep-Pak purification of final doses of radiotracer. Advances in knowledge and implications for patient care. The clinical interest in validation of 68Galabeled agents has increased in the past years due to availability of generators from different vendors (Eckert-Ziegler, ITG, iThemba), favorable approach of U.S. FDA agency to initiate clinical trials, and collaboration of U.S. centers with leading EU clinical sites. The list of 68Ga-labeled tracers evaluated in clinical studies should growth because of the sensitivity of PET technique, the simplicity of the shakebake approach for the dose preparation and reliability of 68Ge/68Ga generators. Our studies have confirmed the reproducible elution profile, and high reliability of ITG GmbH generators required for routine doses preparation according to FDA recommendations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.