Evidence map›Paper›PMID 26695945›Full record

ArticleJournal of fluorescence2016

The Effect of a Fluorophore Photo-Physics on the Lipid Vesicle Diffusion Coefficient Studied by Fluorescence Correlation Spectroscopy.

Dominik Drabik, Magda Przybyło, Aleksander Sikorski, Marek Langner

Open access · hybridAbstract read
In one paragraph

Article in Journal of fluorescence, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Dominik DrabikLaboratory for Biophysics of Macromolecular Aggregates, Department of Biomedical Engineering, Wroclaw University of Technology, Pl. Grunwaldzki 13, 50-377, Wroclaw, Poland. Dominik.Drabik@pwr.edu.pl.
Magda PrzybyłoLaboratory for Biophysics of Macromolecular Aggregates, Department of Biomedical Engineering, Wroclaw University of Technology, Pl. Grunwaldzki 13, 50-377, Wroclaw, Poland.
Aleksander SikorskiLaboratory of Cytobiochemistry, Faculty of Biotechnology, University of Wroclaw, ul. Joliot-Curie 14a, Wrocław, Poland.
Marek LangnerLaboratory for Biophysics of Macromolecular Aggregates, Department of Biomedical Engineering, Wroclaw University of Technology, Pl. Grunwaldzki 13, 50-377, Wroclaw, Poland.
Wrocław University of Science and Technology · PLUniversity of Wrocław · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fluorescence Correlation Spectroscopy (FCS) is a technique, which allows determination of the diffusion coefficient and concentration of fluorescent objects suspended in the solution. The measured parameter is the fluctuation of the fluorescence signal emitted by diffusing molecules. When 100 nm DOPC vesicles labeled with various fluorescent dyes (Fluorescein-PE, NBD-PE, Atto488 DOPE or βBodipy FL) were measured, different values of diffusion coefficients have been obtained. These diffusion coefficients were different from the expected values measured using the dynamic light scattering method (DLS). The FCS was initially developed for solutions containing small fluorescent molecules therefore the observed inconsistency may result from the nature of vesicle suspension itself. The duration of the fluorescence signal may depend on the following factors: the exposure time of the labeled object to the excitation beam, the photo-physical properties (e.g., stability) of a fluorophore, the theoretical model used for the calculations of the diffusion coefficient and optical properties of the vesicle suspension. The diffusion coefficients determined for differently labeled liposomes show that its dependence on vesicle size and quantity of fluorescent probed used for labeling was significant demonstrating that the fluorescence properties of the fluorophore itself (bleaching and/or blinking) were critical factors for a correct outcome of FCS experiment. The new, based on combined FCS and DLS measurements, method for the determination of the focal volume prove itself to be useful for the evaluation of a fluorescence dye with respect to its applicability for FCS experiment.

Indexed as

FluorescenceDiffusionFluorescent DyesGlycerylphosphorylcholineLiposomesModels, TheoreticalPhosphatidylcholinesSpectrometry, Fluorescence1,2-oleoylphosphatidylcholineFluorescent DyesGlycerylphosphorylcholineLiposomesPhosphatidylcholinesBlinkingDynamic light scatteringFluorescence correlation spectroscopyFluorescent probesPhoto-bleaching

Identifiers

PMID26695945
PMCPMC4773467
OpenAlexW2241117501

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.