Evidence map›Paper›PMID 26693487›Full record

ArticleBioMed research international2015

A New Approach Using Manganese-Enhanced MRI to Diagnose Acute Mesenteric Ischemia in a Rabbit Model: Initial Experience.

Da-Wei Zhao, Cheng Cheng, Lian-Qin Kuang, Yu-Long Zhang, Hai-Yun Cheng, Jia-Yan Min, Yi Wang

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 89% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Da-Wei ZhaoDepartment of Radiology, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing 400042, China.ORCID 0000-0002-7817-4719
Cheng ChengDepartment of Radiology, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing 400042, China.
Lian-Qin KuangDepartment of Radiology, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing 400042, China.
Yu-Long ZhangDepartment of Radiology, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing 400042, China.
Hai-Yun ChengDepartment of Radiology, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing 400042, China.
Jia-Yan MinDepartment of Radiology, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing 400042, China.
Yi WangDepartment of Radiology, Institute of Surgery Research, Daping Hospital, Third Military Medical University, Chongqing 400042, China.
Army Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeManganese-enhanced MRI (MEMRI) has been applied to a wide range of biological and disease research. The purpose of the study was to use MEMRI to diagnose the acute mesenteric ischemia (AMI).

methodsThe institutional experimental animal ethics committee approved this study. To optimize the dose of Mn(2+) infusion, a dose-dependent curve was obtained using Mn(2+)-enhanced T 1 map MRI by an intravenous infusion 2.5-20 nmol/g body weight (BW) of 50 nmol/L MnCl2. The eighteen animals were divided into control, sham-operated, and AMI groups. AMI models were performed by ligating the superior mesenteric artery (SMA). T 1 values were measured on T 1 maps in regions of the small intestinal wall and relaxation rate (ΔR 1) was calculated.

resultsA nonlinear relationship between infused MnCl2 solution dose and increase in small intestinal wall ΔR 1 was observed. Control animal exhibited significant Mn(2+) clearance over time at the dose of 15 nmol/g BW. In the AMI model, ΔR 1 values (0.95 ± 0.13) in the small intestinal wall were significantly lower than in control group (2.05 ± 0.19) after Mn(2+) infusion (P < 0.01).

conclusionThe data suggest that MEMRI shows potential as a diagnostic technique that is directly sensitive to the poor or absent perfusion in AMI.

Indexed as

AnimalsChloridesContrast MediaDisease Models, AnimalHumansIntestine, SmallMagnetic Resonance ImagingManganese CompoundsMesenteric IschemiaRabbitsRadiographyChloridesContrast Mediamanganese chlorideManganese Compounds

Identifiers

PMID26693487
PMCPMC4674585
OpenAlexW2178622608

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.