Evidence map›Paper›PMID 26686336›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2016

Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries.

Oliver Lindner, Thomas N B Pascual, Mathew Mercuri, Wanda Acampa, Wolfgang Burchert, Albert Flotats, Philipp A Kaufmann, Anastasia Kitsiou, Juhani Knuuti, S Richard Underwood and 10 more

Abstract read
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Drivers of radiation dose reduction with myocardial perfusion imaging: A large health system experience.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  7. Review
  8. Reducing radiation exposure from nuclear myocardial perfusion imaging: Time to act is now.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017
    Article
  9. Current status of stress myocardial perfusion imaging pharmaceuticals and radiation exposure in Japan: Results from a nationwide survey.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017
    Article
  10. Nuclear cardiology practice in Spain.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017
    Article
  11. Detection of ischemia with early myocardial perfusion imaging: You see more if you watch before.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017
    Article
  12. Status of cardiovascular PET radiation exposure and strategies for reduction: An Information Statement from the Cardiovascular PET Task Force.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017
    Article
  13. Myocardial perfusion SPECT 2015 in Germany. Results of the 7Nuklearmedizin. Nuclear medicine · 2017
    Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors.

Oliver LindnerInstitute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia Bochum, University Hospital of the Ruhr University, Georgstr. 11, 32545, Bad Oeynhausen, Germany. olindner@hdz-nrw.de.
Thomas N B PascualSection of Nuclear Medicine and Diagnostic Imaging, Division of Human Health, International Atomic Energy Agency, Vienna, Austria.
Mathew MercuriDivision of Cardiology, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, NY, USA.
Wanda AcampaInstitute of Biostructures and Bioimaging, National Council of Research, Naples, Italy.
Wolfgang BurchertInstitute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia Bochum, University Hospital of the Ruhr University, Georgstr. 11, 32545, Bad Oeynhausen, Germany.
Albert FlotatsNuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autónoma de Barcelona, Barcelona, Spain.
Philipp A KaufmannDepartment of Nuclear Medicine and Cardiac Imaging, University Hospital Zurich, Zurich, Switzerland.
Anastasia KitsiouDepartment of Cardiology, Sismanoglio Hospital, Athens, Greece.
Juhani KnuutiTurku PET Centre, University of Turku, and Turku University Hospital, Turku, Finland.
S Richard UnderwoodNational Heart and Lung Institute, Imperial College London, London, UK.
João V VitolaQuanta Diagnóstico & Terapia, Curitiba, Brazil.
John J MahmarianDepartment of Cardiology, Houston Methodist DeBakey Heart and Vascular Center, Houston, TX, USA.
Ganesan KarthikeyanDepartment of Cardiology, All India Institute of Medical Sciences, New Delhi, India.
Nathan BetterDepartment of Nuclear Medicine, Royal Melbourne Hospital and University of Melbourne, Melbourne, Australia.
Madan M RehaniRadiation Protection of Patients Unit, International Atomic Energy Agency, Vienna, Austria.
Ravi KashyapSection of Nuclear Medicine and Diagnostic Imaging, Division of Human Health, International Atomic Energy Agency, Vienna, Austria.
Maurizio DondiSection of Nuclear Medicine and Diagnostic Imaging, Division of Human Health, International Atomic Energy Agency, Vienna, Austria.
Diana PaezSection of Nuclear Medicine and Diagnostic Imaging, Division of Human Health, International Atomic Energy Agency, Vienna, Austria.
Andrew J EinsteinDivision of Cardiology, Department of Medicine, Columbia University Medical Center and New York-Presbyterian Hospital, New York, NY, USA.
INCAPS Investigators Group

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeNuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis.

methodsIn March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW).

resultsData on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used.

conclusionIn Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.

Indexed as

Practice Guidelines as TopicRadiation DosageCardiac Imaging TechniquesCardiologyEuropean UnionNuclear MedicinePositron-Emission TomographySocieties, ScientificBest practicesEuropeMyocardial perfusion scintigraphyNuclear cardiologyPETQuality of careRadiation doseSPECT

Identifiers

PMID26686336
PMCPMC4764636

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.