A study to quantify the effect of patient motion and develop methods to detect and correct for motion during myocardial perfusion imaging on a CZT solid-state dedicated cardiac camera.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 14 citations in OpenAlex.
- Improving multi-pinhole CZT myocardial perfusion imaging specificity without changing sensibility by using adapted filter parameters.EJNMMI research · 2024Article
- Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software.Journal of personalized medicine · 2021Article
- Mask-Related Motion Artifact on 99mTc-MIBI SPECT: Unexpected Pitfalls of SARS-CoV-2 Countermeasures.Diagnostics (Basel, Switzerland) · 2021Article
- Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.European journal of nuclear medicine and molecular imaging · 2019Article
- Rotating and stationary SPECT system patient motion myocardial perfusion artifacts.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- Compared vulnerabilities to small cardiac motions between different cameras used for myocardial perfusion imaging.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- Dedicated cardiac CZT SPECT is steadily moving to achieve its destiny.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
- Value of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
Corrections and comments
- Commented on by
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
Abstract
backgroundDue to differences in the design and acquisition parameters on the solid-state CZT cardiac camera the effect of patient motion may vary compared to Anger cameras. This study evaluates the effect of motion, two new methods of three-dimensional (3D) motion detection and a method of motion correction.
methodPhantom acquisitions were offset in the X, Y, and Z directions and combined to simulate different types of motion. Motion artifacts were identified using the total perfusion defect and blinded visual interpretation. Motion was detected by registering planar and reconstructed 30 second images, and corrected by summing the aligned reconstructed images. Validation was performed on phantom data. These techniques were then applied to 40 patient studies.
resultsMotion ≥10 mm and ≥60 seconds in duration introduced significant artifacts. There was no significant difference (P = .258) between the two methods of motion detection. Motion correction removed artifacts from 9/10 phantom simulations. Superior-inferior motion ≥8 mm was measured on 10% of patient studies, and 5% were affected by motion. Motion in the lateral and anterior-posterior directions was <8 mm.
conclusionSuperior-inferior patient motion artifacts have been identified on myocardial perfusion images acquired on a CZT camera. Routine QC to identify studies with significant motion is recommended.