Evidence map›Paper›PMID 26680213›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2016

Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions.

Andreas Schaefer, Matthias Linder, Hendrik Treede, Florian Deuschl, Niklas Schofer, Moritz Seiffert, Yvonne Schneeberger, Stefan Blankenberg, Hermann Reichenspurner, Ulrich Schaefer and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 15 citations in OpenAlex.

  1. Comparison of Latest Generation Intra- and Supra-Annular Self-Expanding Transcatheter Heart Valves for Aortic Valve-in-Valve Procedures.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025
    Article
  2. Feasibility and outcome of third-generation transcatheter aortic valve implantation in patients with extra-large aortic annulus.Clinical research in cardiology : official journal of the German Cardiac Society · 2024
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Transcatheter valve-in-valve implantation (VinV-TAVR) for failed surgical aortic bioprosthetic valves.Clinical research in cardiology : official journal of the German Cardiac Society · 2019
    Article
  9. Late migration of Edwards SAPIEN 3 transcatheter heart valves: mechanisms and transcatheter treatment options for a rare phenomenon.Clinical research in cardiology : official journal of the German Cardiac Society · 2018
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Andreas SchaeferDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany. and.schaefer@uke.de.
Matthias LinderDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Hendrik TreedeDepartment of Cardiac and Thoracic Surgery, University Hospital Halle, Ernst-Grube-Straße 40, 06120, Halle (Saale), Germany.
Florian DeuschlDepartment of General and Interventional Cardiology, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Niklas SchoferDepartment of General and Interventional Cardiology, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Moritz SeiffertDepartment of General and Interventional Cardiology, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Yvonne SchneebergerDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Stefan BlankenbergDepartment of General and Interventional Cardiology, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Hermann ReichenspurnerDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Ulrich SchaeferDepartment of General and Interventional Cardiology, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Lenard ConradiDepartment of Cardiovascular Surgery, University Heart Center Hamburg, Martinistraße 52, 20246, Hamburg, Germany.
Universität Hamburg · DEUniversity Medical Center Hamburg-Eppendorf · DEUniversity Hospital in Halle · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesPhysicians are frequently confronted with patients suffering from aortic stenosis with annular diameters exceeding dimensions in which currently available transcatheter heart valves (THV) are formally approved. Experience in patients receiving significantly undersized Sapien 3 (S3) THV (Edwards Lifesciences, Inc., Irvine, CA, USA) in aortic annuli up to 32 mm has not been reported so far.

methodsPatients with aortic annuli exceeding the formally determined upper size limit and who received a 29 mm S3, were identified from our database. Calcification pattern and annulus dimension were analyzed retrospectively using the 3mensio Medical Imaging software. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-2 definitions.

results21 consecutive patients with aortic annuli ≥28.1 mm received a 29 mm THV. All patients were male (77.4 ± 8.1 year, logEuroSCORE I 22.5 ± 14.1 %). Multi-slice computed tomography and transesophageal echocardiography derived annular dimensions were 30.2 ± 1.5 vs. 28.8 ± 0.9 mm (p = 0.0001). Total calcium load of the aortic valves was 1327 ± 957 mm(3). Device success according to VARC-2 definitions was achieved in 100 % (21/21). All-cause 30-day mortality was 0 % (0/21). Rate of permanent pacemaker implantation was 14.3 % (3/21). No paravalvular leakage ≥ grade II was detectable.

conclusionsPreliminary experience suggests implantation of this type of THV in aortic annuli up to 32 mm to be feasible and safe, in particular calcification patterns. It does not result in a relevant incidence of PVL ≥ grade II, or increased rate of VARC-2 adjudicated clinical endpoints. Also, functional outcomes regarding transvalvular gradients or EOA demonstrate applicability of this THV in such patients.

Indexed as

Balloon ValvuloplastyHeart Valve ProsthesisProsthesis DesignAgedAged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisArrhythmias, CardiacCalcinosisCardiac CatheterizationCardiac Pacing, ArtificialDatabases, FactualEchocardiography, TransesophagealFeasibility StudiesFemaleAortic annulusMSCTTAVITEETHV

Identifiers

PMID26680213
OpenAlexW2301095515

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.