ArticleSpine2016
MRI-Guided Stereotactic System for Delivery of Intraspinal Microstimulation.
Article in Spine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04283812 (A Re-attachable Stereotactic Frame System for Clinical Interventive Neurosurgery), which is not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Re-attachable Stereotactic Frame System for Clinical Interventive Neurosurgery
Who cites it
8 citing papers in PubMed, 14 citations in OpenAlex.
- Design and Evaluation of a Needle Manipulation System with EM Tracking for CT-Guided Spinal Injections.... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2025Article
- Comparative neuroanatomy of the lumbosacral spinal cord of the rat, cat, pig, monkey, and human.Scientific reports · 2021Article
- Intraspinal stimulation with a silicon-based 3D chronic microelectrode array for bladder voiding in cats.Journal of neural engineering · 2020Article
- A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model.Journal of neural engineering · 2018Article
- A Brain-Spinal Interface (BSI) System-on-Chip (SoC) for Closed-Loop Cortically-Controlled Intraspinal Microstimulation.Analog integrated circuits and signal processing · 2018Article
- The Role of Functional Neuroanatomy of the Lumbar Spinal Cord in Effect of Epidural Stimulation.Frontiers in neuroanatomy · 2017Article
- Intraspinal microstimulation produces over-ground walking in anesthetized cats.Journal of neural engineering · 2016Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
Abstract
STUDY
designLaboratory/animal-based proof of principle study.
objectiveTo validate the accuracy of a magnetic resonance imaging (MRI)-guided stereotactic system for intraspinal electrode targeting and demonstrate the feasibility of such a system for controlling implantation of intraspinal electrodes. SUMMARY OF BACKGROUND DATA: Intraspinal microstimulation (ISMS) is an emerging preclinical therapy, which has shown promise for the restoration of motor function following spinal cord injury. However, targeting inaccuracy associated with existing electrode implantation techniques remains a major barrier preventing clinical translation of ISMS.
methodsSystem accuracy was evaluated using a test phantom comprised of nine target locations. Targeting accuracy was determined by calculating the root mean square error between MRI-generated coordinates and actual frame coordinates required to reach the target positions. System performance was further validated in an anesthetized pig model by performing MRI-guided intraspinal electrode implantation and stimulation followed by computed tomography of electrode location. Finally, system compatibility with a commercially available microelectrode array was demonstrated by implanting the array and applying a selection of stimulation amplitudes that evoked hind limb responses.
resultsThe root mean square error between actual frame coordinates and software coordinates, both acquired using the test phantom, was 1.09 ± 0.20 mm. Postoperative computed tomography in the anesthetized pig confirmed spatially accurate electrode placement relative to preoperative MRI. Additionally, MRI-guided delivery of a microwire electrode followed by ISMS evoked repeatable electromyography responses in the biceps femoris muscle. Finally, delivery of a microelectrode array produced repeatable and graded hind limb evoked movements.
conclusionWe present a novel frame-based stereotactic system for targeting and delivery of intraspinal instrumentation. This system utilizes MRI guidance to account for variations in anatomy between subjects, thereby improving upon existing ISMS electrode implantation techniques. LEVEL OF EVIDENCE: N/A.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.