Evidence map›Paper›PMID 26676979›Full record

ArticlePathology oncology research : POR2016

The Influence of Treatment Position (Prone vs. Supine) on Clip Displacement, Seroma, Tumor Bed and Partial Breast Target Volumes: Comparative Study.

Ferenc Lakosi, Akos Gulyban, Selma Ben-Mustapha Simoni, Paul Viet Nguyen, Séverine Cucchiaro, Laurence Seidel, Levente Janvary, Sophie Nicolas, Peter Vavassis, Philippe Coucke

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Pathology oncology research : POR, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ferenc LakosiDepartment of Radiation Oncology, University Hospital of Liège, Domain University of Sart Tilman, B.35, B-4000, Liège 1, Belgium. lakosiferenc@yahoo.com.
Akos GulybanDepartment of Radiation Oncology, University Hospital of Liège, Domain University of Sart Tilman, B.35, B-4000, Liège 1, Belgium.
Selma Ben-Mustapha SimoniDepartment of Radiation Oncology, University Hospital of Liège, Domain University of Sart Tilman, B.35, B-4000, Liège 1, Belgium.
Paul Viet NguyenDepartment of Radiation Oncology, University Hospital of Liège, Domain University of Sart Tilman, B.35, B-4000, Liège 1, Belgium.
Séverine CucchiaroDepartment of Radiation Oncology, University Hospital of Liège, Domain University of Sart Tilman, B.35, B-4000, Liège 1, Belgium.
Laurence SeidelDepartment of Biostatistics, University Hospital of Liège, Liège, Belgium.
Levente JanvaryDepartment of Radiation Oncology, Debrecen University, Debrecen, Hungary.
Sophie NicolasDepartment of Radiation Oncology, University Hospital of Liège, Domain University of Sart Tilman, B.35, B-4000, Liège 1, Belgium.
Peter VavassisDepartment of Radiation Oncology, Hôpital Maisonneuve-Rosemont, Montreal, Québec, Canada.
Philippe CouckeDepartment of Radiation Oncology, University Hospital of Liège, Domain University of Sart Tilman, B.35, B-4000, Liège 1, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To analyse the displacement of surgical clips in prone (Pr) position and assess the consequences on target volumes and integral dose of partial breast irradiation (PBI). 30 post-lumpectomy breast cancer patients underwent CT imaging in supine (Su) and Pr. Clip displacements were measured by the distances from the clips to a common fix bony reference point. On each dataset, the tumour bed (TB = clips ± seroma), clinical target volume (CTV = TB + 1.5 cm) and planning target volumes (PTV = CTV + 1 cm) for PBI were determined and the volume pairs were compared. Furthermore estimation of integral dose ratio (IDR) within the breast from tangential treatment was performed as the ratio of the irradiated breast volume and the volume encompassing all clips. Clips close to the chest wall (CW) in Su showed significantly less displacement in Pr. The mean volumes of seroma, CTV and PTV were significantly higher in Pr than in Su. The PTV volume difference (Pr-Su) was significantly higher in patients with presence of seroma, deep clips and TB location in the superior-internal-quadrant (SIQ) and at the junction of superior quadrants (jSQ). In a multivariate analysis two factors remained significant: seroma and TB localization in SIQ-jSQ. The IDR was significantly larger in Su than in Pr (7.6 vs. 4.1 p < 0.01). Clip displacements varied considerably with respect to their relative position to the CW. In selected patients Pr position potentially leads to a significant increase in target volumes of PBI. Tangential beam arrangement for PBI should be avoided, not only in Su but in Pr as well in case of clip-based target volume definition.

Indexed as

AdultAgedBreastBreast NeoplasmsFemaleHumansMastectomy, SegmentalMiddle AgedProne PositionSeromaSupine PositionSurgical InstrumentsThoracic WallTomography, X-Ray ComputedBreast cancerPartial breast irradiationProne breast radiotherapyTarget volume

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.