ArticleMedical & biological engineering & computing2016
Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis.
Article in Medical & biological engineering & computing, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 14 citations in OpenAlex.
- Beyond mechanical revascularization: thrombo-inflammatory mechanisms and vascular bed-specific design of intracranial stents.Frontiers in molecular biosciences · 2026Review
- Abdominal Stent Graft Numerical Models to Virtually Simulate Endovascular Aortic Repair: A Scoping Review.EJVES vascular forum · 2026Review
- Article
- Hemodynamics in the treatment of pseudoaneurysm caused by extreme constriction of aortic arch with coated stent.Frontiers in cardiovascular medicine · 2024Article
- Computational Fluid Dynamics Support for Fontan Planning in Minutes, Not Hours: The Next Step in Clinical Pre-Interventional Simulations.Journal of cardiovascular translational research · 2022Article
- A Lagrangian cylindrical coordinate system for characterizing dynamic surface geometry of tubular anatomic structures.Medical & biological engineering & computing · 2018Article
- Synchrotron radiation computed tomography versus conventional computed tomography for assessment of four types of stent grafts used for endovascular treatment of thoracic and abdominal aortic aneurysms.Quantitative imaging in medicine and surgery · 2018Article
- Coupling of shear-circumferential stress pulses investigation through stress phase angle in FSI models of stenotic artery using experimental data.Medical & biological engineering & computing · 2017Article
- Occlusive Shrinkage of Ovation Endograft Presenting as Acute Lower Limb Ischemia: Effective Endovascular Management.Aorta (Stamford, Conn.) · 2017Article
- Patient-Specific, Multi-Scale Modeling of Neointimal Hyperplasia in Vein Grafts.Frontiers in physiology · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The current study aims to computationally evaluate the hemodynamic impact of a novel sealing mechanism employed by a recently developed endograft (Ovation TriVascular Stent-Graft System) for endovascular aneurysm repair. The exploitation of two inflatable O-rings to achieve sealing may be advantageous in terms of accommodating challenging anatomies, but comes at a price of a marked inflow stenosis. Here, four representative patient cases of inflow stenosis ranging from 30 to 80 % were analyzed. Lumen surface models were constructed from 1 month post-operative computed tomography images and then used to numerically compute the complex endograft flow field. Our results highlight coexistence of stenotic wall regions exposed to high shear rate and post-stenotic recirculation zones. These conditions may implicate platelet activation and predispose thrombus formation and thromboembolic complications. A clinically insignificant cycle-averaged pressure drop along the inflow stenosis and further in the endograft main body legs was predicted (range 0.01-1.72 mmHg) which was, however, notable at peak systole (range 3.52-19.73 mmHg). Although the functional impact of the endograft stenosis at rest flow conditions may appear insignificant, increased flow rate during exercise is expected to strongly accentuate the observed effects. Pressure drop in the endograft legs was attributed to suboptimal, based on Murray's scaling law, cross-sectional area ratio between trunk and legs of the device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials