Evidence map›Paper›PMID 26676030›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2017

Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects.

Irene Polycarpou, Isabelle Chrysanthou-Baustert, Ourania Demetriadou, Yiannis Parpottas, Christoforos Panagidis, Paul K Marsden, Lefteris Livieratos

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Acquisition time reduction in pediatricJournal of applied clinical medical physics · 2023
    Article
  4. A moving liver phantom in an anthropomorphic thorax for SPECT MP imaging.Physical and engineering sciences in medicine · 2022
    Article
  5. Comparison of ejection fraction calculation between CT and SPECT at high heart rate: A dynamic cardiac phantom study.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  6. Article
  7. Respiratory motion reduction with a dual gating approach in myocardial perfusion SPECT: Effect on left ventricular functional parameters.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018
    Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Irene PolycarpouDivision of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom. irene.polycarpou@kcl.ac.uk.
Isabelle Chrysanthou-BaustertFrederick Research Center, Nicosia, Cyprus.
Ourania DemetriadouDepartment of Nuclear Medicine, Limassol General Hospital, Limassol, Cyprus.
Yiannis ParpottasFrederick Research Center, Nicosia, Cyprus.
Christoforos PanagidisDepartment of Nuclear Medicine, Nicosia General Hospital, Nicosia, Cyprus.
Paul K MarsdenDivision of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.
Lefteris LivieratosDivision of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this study was to determine the impact of respiratory motion correction on SPECT MPI and on defect detection using a phantom assembly.

methodsSPECT/CT data were acquired using an anthropomorphic phantom with inflatable lungs and with an ECG beating and moving cardiac compartment. The heart motion followed the respiratory pattern in the cranio-caudal direction to simulate normal or deep breathing. Small or large transmural defects were inserted into the myocardial wall of the left ventricle. SPECT/CT images were acquired for each of the four respiratory phases, from exhale to inhale. A respiratory motion correction was applied using an image-based method with transformation parameters derived from the SPECT data by a non-rigid registration algorithm. A report on defect detection from two physicians and a quantitative analysis on MPI data were performed before and after applying motion correction.

resultsRespiratory motion correction eliminated artifacts present in the images, resulting in a uniform uptake and reduction of motion blurring, especially in the inferior and anterior regions of the LV myocardial walls. The physicians' report after motion correction showed that images were corrected for motion.

conclusionsA combination of motion correction with attenuation correction reduces artifacts in SPECT MPI. AC-SPECT images with and without motion correction should be simultaneously inspected to report on small defects.

Indexed as

Phantoms, ImagingRespirationHeart DiseasesHumansMotionMyocardial Perfusion ImagingSingle Photon Emission Computed Tomography Computed Tomographycranio-caudal cardiac motionmotion correctionmyocardial perfusion defectsSPECT/CT

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.