Evidence map›Paper›PMID 26673037›Full record

ArticleOrthopaedic journal of sports medicine2015

Surgical and Functional Outcomes in Patients Undergoing Total Knee Replacement With Patient-Specific Implants Compared With "Off-the-Shelf" Implants.

Ran Schwarzkopf, Merrick Brodsky, Giancarlo A Garcia, Andreas H Gomoll

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed, 5 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed, 5 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. Review
  18. Article
  19. Three-dimensional Printing in Orthopaedic Surgery: Current Applications and Future Developments.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2021
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ran SchwarzkopfDepartment of Orthopaedic Surgery, Joint Replacement Service, University of California-Irvine, Orange, California, USA.
Merrick BrodskyDepartment of Orthopaedic Surgery, Joint Replacement Service, University of California-Irvine, Orange, California, USA.
Giancarlo A GarciaDepartment of Orthopaedic Surgery, Joint Replacement Service, University of California-Irvine, Orange, California, USA.
Andreas H GomollDepartment of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTotal knee arthroplasty (TKA) instrumentation and implant designs have been evolving, with one of the current innovations being patient-specific implants (PSIs). PURPOSE: To evaluate whether there is a significant difference in surgical time, intraoperative blood loss, postoperative range of motion, and length of stay between PSI and conventional TKA. STUDY

designCohort study; Level of evidence, 3.

methodsA consecutive series of 621 TKA patients, 307 with PSIs and 314 with conventional implants, was reviewed. Differences in estimated blood loss, length of stay, range of motion, and surgical time/tourniquet time between the 2 cohorts were analyzed.

resultsLinear regression analysis demonstrated that PSI decreased estimated blood loss by 44.72 mL (P < .01), decreased length of stay by 0.39 days (P < .01), decreased postoperative range of motion by 3.90° (P < .01), and had a negligible difference on surgical and tourniquet time.

conclusionThe use of PSI is associated with decreased estimated blood loss, decreased length of stay, decreased range of motion, and no discernible difference in surgical or tourniquet time, all of which are unlikely to be clinically significant.

Indexed as

estimated blood losslength of staypatient-specific implantsrange of motionsurgical timetotal knee arthroplastytourniquet time

Identifiers

PMID26673037
PMCPMC4622326

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.