Evidence map›Paper›PMID 26669592›Full record

ArticleClinical neuroradiology2017

Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms.

A E Othman, S Afat, C Brockmann, O Nikoubashman, G Bier, M A Brockmann, K Nikolaou, J H Tai, Z P Yang, J H Kim and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical neuroradiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

A E OthmanDepartment of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, 52074, Aachen, Germany.
S AfatDepartment of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, 52074, Aachen, Germany.
C BrockmannDepartment of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, 52074, Aachen, Germany.
O NikoubashmanDepartment of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, 52074, Aachen, Germany.
G BierDepartment for Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, University Hospital Tuebingen, 72076, Tübingen, Germany.
M A BrockmannDepartment of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, 52074, Aachen, Germany.
K NikolaouDepartment for Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, University Hospital Tuebingen, 72076, Tübingen, Germany.
J H TaiCenter for Medical-IT Convergence Technology Research, Advanced Institute of Convergence Technology, 433-270, Suwon, South Korea.
Z P YangDepartment of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, 433-270, Suwon, South Korea.
J H KimDepartment of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, 433-270, Suwon, South Korea. kimjhyo@snu.ac.kr.
M WiesmannDepartment of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, 52074, Aachen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe aimed to compare different computed tomography (CT) perfusion post-processing algorithms regarding image quality of perfusion maps from low-dose volume perfusion CT (VPCT) and their diagnostic performance regarding the detection of ischemic brain lesions. METHODS AND MATERIALS: We included VPCT data of 21 patients with acute stroke (onset < 6h), which were acquired at 80 kV and 180 mAs. Low-dose VPCT datasets with 72 mAs (40 % of original dose) were generated using realistic low-dose simulation. Perfusion maps (cerebral blood volume (CBV); cerebral blood flow (CBF) from original and low-dose datasets were generated using two different commercially available post-processing methods: deconvolution-based method (DC) and maximum slope algorithm (MS). The resulting DC and MS perfusion maps were compared regarding perfusion values, signal-to-noise ratio (SNR) as well as image quality and diagnostic accuracy as rated by two blinded neuroradiologists.

resultsQuantitative perfusion parameters highly correlated for both algorithms and both dose levels (r ≥ 0.613, p < 0.001). Regarding SNR levels and image quality of the CBV maps, no significant differences between DC and MS were found (p ≥ 0.683). Low-dose MS CBF maps yielded significantly higher SNR levels (p < 0.001) and quality scores (p = 0.014) than those of DC. Low-dose CBF and CBV maps from both DC and MS yielded high sensitivity and specificity for the detection of ischemic lesions (sensitivity ≥ 0.82, specificity ≥ 0.90).

conclusionOur results indicate that both methods produce diagnostically sufficient perfusion maps from simulated low-dose VPCT. However, MS produced CBF maps with significantly higher image quality and SNR than DC, indicating that MS might be more suitable for low-dose VPCT imaging.

Indexed as

AlgorithmsTomography, X-Ray ComputedAgedAged, 80 and overBrainCerebrovascular CirculationFemaleHumansMaleMiddle AgedRadiation DosageReproducibility of ResultsRetrospective StudiesSensitivity and SpecificityLow-dose perfusion CTPost-processing, Perfusion CTRadiation doseStroke

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.