ArticleAnalytical chemistry2016

Parallel Spectral Acquisition with an Ion Cyclotron Resonance Cell Array.

Sung-Gun Park, Gordon A Anderson, Arti T Navare, James E Bruce

Abstract read
In one paragraph

Article in Analytical chemistry, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. A planar quadrupole device for transmitting and trapping ions in high vacuum.Rapid communications in mass spectrometry : RCM · 2023
    Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Parallel Spectral Acquisition with Orthogonal ICR Cells.Journal of the American Society for Mass Spectrometry · 2017
    Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sung-Gun ParkDepartment of Genome Sciences, University of Washington , Seattle, Washington 98109, United States.
Gordon A AndersonGAA Custom Engineering, LLC, Benton City, Washington 99320, United States.
Arti T NavareDepartment of Genome Sciences, University of Washington , Seattle, Washington 98109, United States.
James E BruceDepartment of Genome Sciences, University of Washington , Seattle, Washington 98109, United States.

Funding

Instrumentation Development: MS Array for Quantitative ProteomicsR01GM097112 · NIGMS · UNIVERSITY OF WASHINGTON · PI BRUCE, JAMES EDWARD · 2011 to 2020
$2.9M
NIGMS NIH HHS 5R01GM097112NIGMS NIH HHS R01 GM097112
6 · The paper itself

Abstract

Mass measurement accuracy is a critical analytical figure-of-merit in most areas of mass spectrometry application. However, the time required for acquisition of high-resolution, high mass accuracy data limits many applications and is an aspect under continual pressure for development. Current efforts target implementation of higher electrostatic and magnetic fields because ion oscillatory frequencies increase linearly with field strength. As such, the time required for spectral acquisition of a given resolving power and mass accuracy decreases linearly with increasing fields. Mass spectrometer developments to include multiple high-resolution detectors that can be operated in parallel could further decrease the acquisition time by a factor of n, the number of detectors. Efforts described here resulted in development of an instrument with a set of Fourier transform ion cyclotron resonance (ICR) cells as detectors that constitute the first MS array capable of parallel high-resolution spectral acquisition. ICR cell array systems consisting of three or five cells were constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. Independent ion populations were injected and trapped within each cell in the array. Upon filling the array, all ions in all cells were simultaneously excited and ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition, parallel mass spectrometry (MS) and MS/MS measurements, and parallel high-resolution acquisition with the MS array system.

Indexed as

CyclotronsFourier AnalysisIonsMass SpectrometryTissue Array AnalysisIons

Identifiers

PMID26669509
PMCPMC4848028

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.