Evidence map›Paper›PMID 26666981›Full record

Trial reportBMC pregnancy and childbirth2015

Clinical impact of the disposable ventouse iCup® versus a metallic vacuum cup: a multicenter randomized controlled trial.

Véronique Equy, Sandra David-Tchouda, Michel Dreyfus, Didier Riethmuller, Françoise Vendittelli, Victoire Cabaud, Bruno Langer, Jennifer Margier, Jean-Luc Bosson, Jean-Patrick Schaal

Registry-linked trialOpen access · goldAbstract readComparative StudyMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in BMC pregnancy and childbirth, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01058200 (Assess the Risk-benefit Balance of the New Vacuum Assisted-delivery Device "iCUP" Versus the Reference Vacuum. Multicenter Prospective Randomized Controlled Study), which is not on this map. Cited by 6 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 3 pooled it
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01058200 phase3completednot on this map

Assess the Risk-benefit Balance of the New Vacuum Assisted-delivery Device "iCUP" Versus the Reference Vacuum. Multicenter Prospective Randomized Controlled Study

TypeinterventionalSponsorUniversity Hospital, GrenobleRan2009 to 2012Enrolled668ConditionsVacuum Extraction, Obstetrical, Randomized Controlled Trials, Failures, Medical Device, Maternal LesionsArmsiCup, reference cup
3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 3 syntheses or guidelines pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Instruments for assisted vaginal birth.The Cochrane database of systematic reviews · 2021
    Pooled it
  3. Pooled it
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 7 institutions in 1 country.

Véronique EquyObstetrical Care Unit, 'Hôpital Couple Enfant', Grenoble University Hospital, CS 10217, 38043, Grenoble cedex 09, France. VEquy@chu-grenoble.fr.
Sandra David-TchoudaGrenoble University Hospital, Clinical and Medico-economic Evaluation Unit - Clinical Research and Innovation Department, Grenoble University Hospital, 38000, Grenoble, France. SDavidtchouda@chu-grenoble.fr.
Michel DreyfusObstetrical Care Unit, 'Hôpital Femme Enfant', Caen University Hospital, 14033, Caen, France. dreyfus-m@chu-caen.fr.
Didier RiethmullerObstetrical Care Unit, 'Pôle Mère-Femme', Besançon University Hospital, 25030, Besançon, France. didier.riethmuller@univ-fcomte.fr.
Françoise VendittelliObstetrical Care Unit, Site Estaing, Clermont-Ferrand University Hospital, 1 place Lucie et Raymond Aubrac, 63003, Clermont-Ferrand Cedex 1, France. fvendittelli@chu-clermontferrand.fr.
Victoire CabaudObstetrical Care Unit, Chambéry Hospital, 73011, Chambéry, France. victoire.cabaud@ch-chambery.fr.
Bruno LangerObstetrical Care Unit, 'Hôpital Hautepierre', Strasbourg University Hospital, 67098, Strasbourg, France. bruno.langer@chru-strasbourg.fr.
Jennifer MargierGrenoble University Hospital, Clinical and Medico-economic Evaluation Unit - Clinical Research and Innovation Department, Grenoble University Hospital, 38000, Grenoble, France. JMargier@chu-grenoble.fr.
Jean-Luc BossonTIMC-Imag UMR 5525, Université Grenoble Alpes, 38000, Grenoble, France. jean-luc.bosson@imag.fr.
Jean-Patrick SchaalObstetrical Care Unit, 'Hôpital Couple Enfant', Grenoble University Hospital, CS 10217, 38043, Grenoble cedex 09, France.
Université Grenoble Alpes · FRCentre Hospitalier Métropole Savoie · FRCentre Hospitalier Universitaire de Besançon · FRCentre Hospitalier Universitaire de Clermont-Ferrand · FRHôpital Couple Enfant · FRHôpital d'Hautepierre · FRHôpital Femme Mère Enfant · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAssisted vaginal delivery by vacuum extraction is frequent. Metallic resterilizible metallic vacuum cups have been routinely used in France. In the last few years a new disposable semi-soft vacuum extraction cup, the iCup, has been introduced. Our objective was to compare maternal and new-born outcomes between this disposable cup and the commonly used Drapier-Faure metallic cup.

methodsThis was a multicenter prospective randomized controlled open clinical trial performed in the maternity units of five university hospitals and one community hospital in France from October 2009 to February 2013. We included consecutive eligible women with a singleton gestation of at least 37 weeks who required vacuum assisted delivery. Women were randomized to vacuum extraction using the iCup or usual Drapier-Faure metallic cup. The primary outcome was a composite criterion including both the risk of cup dysfunction and the most frequent maternal and neonatal harms: the use of other instruments after attempted vacuum extraction, caesarean section after attempted vacuum extraction, three detachments of the cup, caput succedaneum, cephalohaematoma, episiotomy and perineal tears.

results335 women were randomized to the disposable cup and 333 to extraction using the metallic cup. There was no significant difference between the two groups for the primary outcome. However, failed instrumental delivery was more frequent in the disposable cup group, mainly due to detachment: 35.6 % vs 7.1 %, p < 0.0001. Conversely, perineal tears were more frequent in the metallic cup group, especially third or fourth grade perineal tears: 1.7 % versus 5.0 %, p = 0.003. There were no significant differences between the two groups concerning post-partum haemorrhage, transfer to a neonatal intensive care unit (NICU) or serious adverse events.

conclusionsWhile the disposable cup had more detachments and extraction failures than the standard metallic cup, this innovative disposable device had the advantage of fewer perineal injuries.

trial registrationwww.clinicaltrials.gov : NCT01058200 on Jan. 27 2010.

Indexed as

AdultBirth InjuriesEpisiotomyFemaleFranceHumansInfant, NewbornIntensive Care Units, NeonatalLacerationsPerineumPostpartum HemorrhagePregnancyProspective StudiesVacuum Extraction, ObstetricalYoung Adult

Identifiers

PMID26666981
PMCPMC4678725
OpenAlexW2210696885

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.