Evidence map›Paper›PMID 26661645›Full record

ArticleSleep & breathing = Schlaf & Atmung2016

Rates of initial acceptance of PAP masks and outcomes of mask switching.

Adel Bachour, Pirjo Vitikainen, Paula Maasilta

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Sleep & breathing = Schlaf & Atmung, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 45 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Symptoms During CPAP Therapy Are the Major Reason for Contacting the Sleep Unit Between Two Routine Contacts.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2019
    Trial
  4. Article
  5. Article
  6. Article
  7. International Consensus Statement on Obstructive Sleep Apnea.International forum of allergy & rhinology · 2023
    Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Adel BachourSleep Unit, Heart and Lung Centre, Helsinki University Hospital, University of Helsinki, P.O. Box 160, 00029, HUS, Finland. adel.bachour@hus.fi.ORCID http://orcid.org/0000-0002-7367-6613
Pirjo VitikainenSleep Unit, Heart and Lung Centre, Helsinki University Hospital, University of Helsinki, P.O. Box 160, 00029, HUS, Finland.
Paula MaasiltaSleep Unit, Heart and Lung Centre, Helsinki University Hospital, University of Helsinki, P.O. Box 160, 00029, HUS, Finland.
University of Helsinki · FI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRecently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms.

methodsWe prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching.

resultsOur patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks.

conclusionThe initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

Indexed as

MasksPatient Acceptance of Health CareAdultAgedContinuous Positive Airway PressureEquipment DesignFemaleFollow-Up StudiesHumansMaleMiddle AgedOdds RatioPatient DropoutsPolysomnographyProspective StudiesRisk FactorsCPAP interfaceMask switchingOutcomesSide effectsSleep apnea

Identifiers

PMID26661645
OpenAlexW2292457420

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.