Evidence map›Paper›PMID 26658279›Full record

ArticleJournal of neurointerventional surgery2016

Single-center experience in the endovascular treatment of wide-necked intracranial aneurysms with a bridging intra-/extra-aneurysm implant (pCONus).

S Fischer, A Weber, A Titschert, C Brenke, A Kowoll, W Weber

Open access · hybridAbstract read
In one paragraph

Article in Journal of neurointerventional surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 36 citations in OpenAlex.

  1. Review
  2. Review
  3. [Brain aneurysms treatment with pCONus2 device. Initial experience at IMSS].Revista medica del Instituto Mexicano del Seguro Social · 2023
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Re-treatment of an unruptured anterior communicating artery aneurysm using the new pCONus 2 device: Description of a case.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2018
    Article
  9. Article
  10. Combined use of a pCONus and a Solitaire stent: Report of two cases.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2017
    Article
  11. Article
  12. Misaligned pCONus Device: Case Report of a Unique Complication.Journal of clinical imaging science · 2017
    Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

S FischerKnappschaftskrankenhaus Bochum-Langendreer Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin, Bochum, Germany.
A WeberKnappschaftskrankenhaus Bochum-Langendreer Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin, Bochum, Germany.
A TitschertKnappschaftskrankenhaus Bochum-Langendreer Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin, Bochum, Germany.
C BrenkeKnappschaftskrankenhaus Bochum-Langendreer Universitätsklinik, Klinik für Neurochirurgie, Bochum, Germany.
A KowollKnappschaftskrankenhaus Bochum-Langendreer Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin, Bochum, Germany.
W WeberKnappschaftskrankenhaus Bochum-Langendreer Universitätsklinik, Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin, Bochum, Germany.
Universitätsklinikum Knappschaftskrankenhaus Bochum · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo retrospectively evaluate the safety and efficacy of the endovascular treatment of wide-necked intracranial aneurysms assisted by a novel intra-/extra-aneurysm stent-like implant (pCONus).

methodsInitial and follow-up angiographic and clinical results are presented of 25 patients with 25 unruptured and ruptured wide-necked intracranial aneurysms treated by reconstruction of the aneurysm neck using the pCONus implant followed by coil occlusion of the fundus.

resultsSuccessful intra-/extra-aneurysm deployment of the pCONus with coil occlusion of the fundus was achieved in all but one case. Procedure-related ischemic complications were observed in three cases with permanent deterioration in one. Acceptable aneurysm occlusion was achieved in all cases. Follow-up angiography revealed sufficient occlusion in 81.0% of the aneurysms. Intimal hyperplasia in the stented segment of the parent artery or device migration has not been observed to date.

conclusionsThe pCONus device offers a promising treatment option for complex wide-necked bifurcation intracranial aneurysms. Acute or delayed dislocations of coils into the parent artery are successfully avoided.

Indexed as

StentsAdultAgedAneurysm, RupturedCerebral AngiographyEmbolization, TherapeuticEndovascular ProceduresFemaleFollow-Up StudiesHumansIncidental FindingsIntracranial AneurysmMaleMiddle AgedRetrospective StudiesTreatment OutcomeAneurysmCoilDeviceInterventionStent

Identifiers

PMID26658279
PMCPMC5099317
OpenAlexW2194435300

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked