Evidence map›Paper›PMID 26655913›Full record

ArticleEar and hearing

Temporal Response Properties of the Auditory Nerve in Implanted Children with Auditory Neuropathy Spectrum Disorder and Implanted Children with Sensorineural Hearing Loss.

Shuman He, Paul J Abbas, Danielle V Doyle, Tyler C McFayden, Stephen Mulherin

Abstract readComparative Study
In one paragraph

Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Effects of electrical stimulation rate in genetically confirmed pre- and post-Synaptic auditory neuropathy in children.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shuman He1Center for Hearing Research, Boys Town National Research Hospital, Omaha, Nebraska, USA; 2Department of Communication Sciences & Disorders, The University of Iowa, Iowa City, Iowa, USA; 3Department of Hearing and Speech, The Wake Forest Baptist Medical Center, Winston Salem, North Carolina, USA; and 4Department of Computer Science, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
Paul J Abbas
Danielle V Doyle
Tyler C McFayden
Stephen Mulherin

Funding

Speech Production &LanguageP50DC000242 · NIDCD · UNIVERSITY OF IOWA · PI Bruce Jay Gantz · 1989 to 2026
$58.8M
The Impact of Mild Hearing Loss on Auditory Perception in Complex EnvironmentsP20GM109023 · NIGMS · FATHER FLANAGAN'S BOYS' HOME · PI AUBUCHON, ANGELA MARIE · 2014 to 2023
$23.4M
Electrically-evoked neural responses in children with auditory neuropathyR03DC013153 · NIDCD · UNIV OF NORTH CAROLINA CHAPEL HILL · PI HE, SHUMAN · 2013 to 2015
$454k
NIDCD NIH HHS P50 DC000242NIDCD NIH HHS R03 DC013153NIGMS NIH HHS P20 GM109023
6 · The paper itself

Abstract

objectiveThis study aimed to (1) characterize temporal response properties of the auditory nerve in implanted children with auditory neuropathy spectrum disorder (ANSD), and (2) compare results recorded in implanted children with ANSD with those measured in implanted children with sensorineural hearing loss (SNHL).

designParticipants included 28 children with ANSD and 29 children with SNHL. All subjects used cochlear nucleus devices in their test ears. Both ears were tested in 6 children with ANSD and 3 children with SNHL. For all other subjects, only one ear was tested. The electrically evoked compound action potential (ECAP) was measured in response to each of the 33 pulses in a pulse train (excluding the second pulse) for one apical, one middle-array, and one basal electrode. The pulse train was presented in a monopolar-coupled stimulation mode at 4 pulse rates: 500, 900, 1800, and 2400 pulses per second. Response metrics included the averaged amplitude, latencies of response components and response width, the alternating depth and the amount of neural adaptation. These dependent variables were quantified based on the last six ECAPs or the six ECAPs occurring within a time window centered around 11 to 12 msec. A generalized linear mixed model was used to compare these dependent variables between the 2 subject groups. The slope of the linear fit of the normalized ECAP amplitudes (re. amplitude of the first ECAP response) over the duration of the pulse train was used to quantify the amount of ECAP increment over time for a subgroup of 9 subjects.

resultsPulse train-evoked ECAPs were measured in all but 8 subjects (5 with ANSD and 3 with SNHL). ECAPs measured in children with ANSD had smaller amplitude, longer averaged P2 latency and greater response width than children with SNHL. However, differences in these two groups were only observed for some electrodes. No differences in averaged N1 latency or in the alternating depth were observed between children with ANSD and children with SNHL. Neural adaptation measured in these 2 subject groups was comparable for relatively short durations of stimulation (i.e., 11 to 12 msec). Children with ANSD showed greater neural adaptation than children with SNHL for a longer duration of stimulation. Amplitudes of ECAP responses rapidly declined within the first few milliseconds of stimulation, followed by a gradual decline up to 64 msec after stimulus onset in the majority of subjects. This decline exhibited an alternating pattern at some pulse rates. Further increases in pulse rate diminished this alternating pattern. In contrast, ECAPs recorded from at least one stimulating electrode in six ears with ANSD and three ears with SNHL showed a clear increase in amplitude over the time course of stimulation. The slope of linear regression functions measured in these subjects was significantly greater than zero.

conclusionsSome but not all aspects of temporal response properties of the auditory nerve measured in this study differ between implanted children with ANSD and implanted children with SNHL. These differences are observed for some but not all electrodes. A new neural response pattern is identified. Further studies investigating its underlying mechanism and clinical relevance are warranted.

Indexed as

Cochlear ImplantationEvoked Potentials, AuditoryAdolescentChildChild, PreschoolCochlear NerveFemaleHearing Loss, CentralHearing Loss, SensorineuralHumansMaleTime FactorsYoung Adult

Identifiers

PMID26655913
PMCPMC5065100

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.