Evidence map›Paper›PMID 26652613›Full record

ArticleBMC surgery2015

Safety of bioabsorbable implants in vitro.

Mehmet Isyar, Ibrahim Yilmaz, Gurdal Nusran, Olcay Guler, Sercan Yalcin, Mahir Mahirogullari

Open access · goldAbstract read
In one paragraph

Article in BMC surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Mehmet IsyarDepartment of Orthopaedic and Traumatology, Istanbul Medipol University School of Medicine, Bagcilar, 34214, Istanbul, Turkey. misyar2003@yahoo.com.
Ibrahim YilmazDepartment of Pharmacovigilance and Rational Drug Use Team, Pharmacologist Pharmacist, M.Sc. Republic of Turkey, Ministry of Health, State Hospital, 59100, Tekirdag, Turkey. ibrahimyilmaz77@yahoo.com.
Gurdal NusranDepartment of Orthopaedic and Traumatology, Canakkale Onsekizmart University School of Medicine, 17000, Canakkale, Turkey. gnusran@hotmail.com.
Olcay GulerDepartment of Orthopaedic and Traumatology, Istanbul Medipol University School of Medicine, Bagcilar, 34214, Istanbul, Turkey. olcayguler77@gmail.com.
Sercan YalcinDepartment of Orthopaedic and Traumatology, Istanbul Medipol University School of Medicine, Bagcilar, 34214, Istanbul, Turkey. seralple@hotmail.com.
Mahir MahirogullariDepartment of Orthopaedic and Traumatology, Istanbul Medipol University School of Medicine, Bagcilar, 34214, Istanbul, Turkey. mahirogullari@yahoo.com.
Istanbul Medipol University · TRÇanakkale Onsekiz Mart Üniversitesi · TRMinistry of Health · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of the present study was to investigate the safety of bioabsorbable plates and screws in humans.

methodsFor this purpose, an implant system based on [poly(lactic-co-glycolic acids)(85:15)] was designed. The system was tested for pH, temperature, and swelling and then its surface morphology was analyzed for surface porosity using environmental electron microscopy. Then, the effects of this bioabsorbable system on the viability and profileration of osteocytes were examined on a molecular level via in vitro experiments. A [poly(lactic-co-glycolic acids)(90:10)] bioabsorbable implant, which is commercially available and used in orthopedic surgery, was used as control group. For the statistical evaluation of the data obtained in the present study, the groups were compared by Tukey HSD test following ANOVA. The significance level was set as p < 0.05.

resultsIt was observed that the osteocytes cultivated on the PLGA system designed in the present study included more live cells and allowed more proliferation compared to the control.

conclusionOne of the criteria in the selection of implants for orthopedic surgery is that a good implant should not need removal and thus a second surgery. In the present study, a bioabsorbable implant was designed considering this criterion. The present study is the first step to prove the safety of this new design by in vitro toxicity and viability experiments.

Indexed as

Absorbable ImplantsBone PlatesBone ScrewsMaterials TestingCell ProliferationCells, CulturedHumansLactic AcidOsteocytesPolyestersPolymersLactic AcidPolyesterspoly(lactide)Polymers

Identifiers

PMID26652613
PMCPMC4676853
OpenAlexW2203779263

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.