Evidence map›Paper›PMID 26646263›Full record

ArticleLa Radiologia medica2016

Flat detector C-arm CT-guided transthoracic needle biopsy of small (≤2.0 cm) pulmonary nodules: diagnostic accuracy and complication in 100 patients.

Dechao Jiao, Huifeng Yuan, Quanhui Zhang, Xinwei Han

Abstract read
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Clinical role of guidance by C-arm CT forLa Radiologia medica · 2017
    Article
  9. Article
  10. Biopsy first: Lessons learned from Cancer and Leukemia Group B (CALGB) 140503.The Journal of thoracic and cardiovascular surgery · 2017
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Dechao JiaoDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Huifeng YuanDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Quanhui ZhangDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China.
Xinwei HanDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, Henan, People's Republic of China. 13592583911@163.com.
First Affiliated Hospital of Zhengzhou University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed at assessing the usefulness of flat detector cone-beam CT virtual navigation-guided transthoracic needle biopsy of small (≤2.0 cm) pulmonary nodules in terms of diagnostic accuracy and complications to evaluate the diagnostic performance and complications of small pulmonary nodules under cone-beam CT (CBCT) guidance. MATERIALS AND

methodsA total of 100 patients with 100 solid lung nodules were retrospectively enrolled to undergo transthoracic needle biopsy (TNB) procedures. The mean diameter of lesions was 1.25 cm ± 0.39 (range 0.50-2.00 cm). The needle path was carefully planned and calculated on the CBCT virtual navigation guidance system, which acquired 3D CT-like cross-sectional images. Diagnostic performance, complication rate, and patient radiation exposure were investigated.

resultsThe technical success rate of TNB under iGuide CBCT virtual navigation system was 99% (99/100). The sensitivity, specificity, and accuracy of TNB of small nodules under iGuide CBCT virtual navigation guidance were 98.7% (77/78), 90.5% (19/21), and 97.0% (96/99), respectively. The number of pleural passages with coaxial needle, biopsies, and CBCT acquisitions were 1.09 ± 0.32, 1.20 ± 0.47, and 3.06 ± 1.35, respectively. Complications occurred in 22 (22%) cases. The mean total procedure time was 12.84 min ± 3.74, resulting in a mean exposure dose of 7.6 mSv ±3.1.

conclusionsFlat detector Cone-beam CT-guided TNB is a highly accurate and safe diagnostic method for small (≤2.0 cm) lung nodule.

Indexed as

AdultAgedAged, 80 and overBiopsy, NeedleFemaleHumansImage-Guided BiopsyLung NeoplasmsMaleMiddle AgedMultiple Pulmonary NodulesRetrospective StudiesTomography, X-Ray ComputedYoung AdultBiopsyComputer applications-3DInterventionalLung

Identifiers

PMID26646263
OpenAlexW2196410946

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.