Evidence map›Paper›PMID 26645707›Full record

ArticleNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation2016

Echocardiography and cardiac resynchronisation therapy, friends or foes?

W M van Everdingen, J C Schipper, J van 't Sant, K Ramdat Misier, M Meine, M J Cramer

Erratum issuedAbstract read
In one paragraph

Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. The stethoscope: celebration or cremation after 200 years?Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2016
    Article
  11. Current aspects of cardiac resynchronisation therapy.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2016
    Article
  12. Article
  13. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

W M van EverdingenDepartment of Cardiology, University Medical Centre Utrecht, Heidelberglaan 100, PO Box 85500, 3508 GA, Utrecht, The Netherlands. w.m.vaneverdingen@umcutrecht.nl.
J C SchipperDepartment of Cardiology, University Medical Centre Utrecht, Heidelberglaan 100, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
J van 't SantDepartment of Cardiology, University Medical Centre Utrecht, Heidelberglaan 100, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
K Ramdat MisierDepartment of Cardiology, University Medical Centre Utrecht, Heidelberglaan 100, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
M MeineDepartment of Cardiology, University Medical Centre Utrecht, Heidelberglaan 100, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
M J CramerDepartment of Cardiology, University Medical Centre Utrecht, Heidelberglaan 100, PO Box 85500, 3508 GA, Utrecht, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.

Indexed as

3D echocardiographyCardiac resynchronisation therapyDeformation imagingDyssynchronyEchocardiographyFollow-upInterobserver variabilityOptimisationResponseSeptal strainSpeckle tracking echocardiographyVolume

Identifiers

PMID26645707
PMCPMC4692834

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked