Evidence map›Paper›PMID 26636974›Full record

ArticlePloS one2015

Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation towards Practical Non-Invasive Measurement of Blood Constituents.

Takehiro Yamakoshi, Jihyoung Lee, Kenta Matsumura, Yasuhiro Yamakoshi, Peter Rolfe, Daiki Kiyohara, Ken-ichi Yamakoshi

Abstract readComparative Study
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. CMOS-Compatible ZrOACS applied materials & interfaces · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Device and Method for Noninvasive Glucose Assessment.Journal of diabetes science and technology · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Takehiro YamakoshiDepartment of Information and Systems Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi Higashi-ku, Fukuoka-shi, Fukuoka, 811-0295, Japan.
Jihyoung LeeDepartment of Information and Systems Engineering, Faculty of Information Engineering, Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi Higashi-ku, Fukuoka-shi, Fukuoka, 811-0295, Japan.
Kenta MatsumuraDivision of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Kita 14 Nishi 9, Kita-ku, Sapporo-shi, Hokkaido, 060-0814, Japan.
Yasuhiro YamakoshiDivision of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Kita 14 Nishi 9, Kita-ku, Sapporo-shi, Hokkaido, 060-0814, Japan.
Peter RolfeDepartment of Automatic Measurement and Control, Harbin Institute of Technology, 92 West Dazhi Street, Nan Gang District, Harbin, 150001, China.
Daiki KiyoharaGraduate School of Natural Science and Technology, Kanazawa University, Kakuma-machi, Kanazawa-shi, Ishikawa, 920-1192, Japan.
Ken-ichi YamakoshiShowa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, 142-8555, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to compare conventional photoplethysmography (PPG) in a finger with PPG using an integrating sphere (ISPPG) to enhance scattered light collection. Two representative wavelengths were used; 1160 nm, a window through the absorption spectra of water and alcohol, and 1600 nm around where water absorption is high and there is an absorption peak of blood glucose. Simultaneous transmission-type measurements were made with conventional PPG and with ISPPG for each wavelength in the tips of index fingers of both hands in a total of 10 healthy young male and female volunteers (21.7 ± 1.6 years old). During a 5 min period in which subjects were in a relaxed state we determined the signal-to-noise ratio, SNR, and the PPG detectability (or sensitivity) by the two techniques. SNR during the test period was significantly higher with ISPPG as compared with conventional PPG, especially for the 1600 nm wavelength. PPG signals with 1600 nm could scarcely be detected by conventional PPG, while they could be detected with good sensitively by ISPPG. We conclude that under controlled conditions ISPPG has better SNR and higher sensitivity than conventional transmission PPG, especially in wavelength regions where water absorption is high but where there is potential for practical measurement of blood constituents including glucose.

Indexed as

FemaleFingersHumansMalePhotoplethysmographySignal-To-Noise RatioYoung Adult

Identifiers

PMID26636974
PMCPMC4670230

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials