SynthesisBMC pulmonary medicine2015
Diagnostic accuracy of nasal nitric oxide for establishing diagnosis of primary ciliary dyskinesia: a meta-analysis.
Synthesis in BMC pulmonary medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 4 syntheses or guidelines pooled it.
- Nasal Nitric Oxide Measurement in Primary Ciliary Dyskinesia. A Technical Paper on Standardized Testing Protocols.Annals of the American Thoracic Society · 2020Guideline
- Diagnosis of Primary Ciliary Dyskinesia. An Official American Thoracic Society Clinical Practice Guideline.American journal of respiratory and critical care medicine · 2018Pooled it
- Accuracy of Nasal Nitric Oxide Measurement as a Diagnostic Test for Primary Ciliary Dyskinesia. A Systematic Review and Meta-analysis.Annals of the American Thoracic Society · 2017Pooled it
- Prevalence of primary ciliary dyskinesia in consecutive referrals of suspect cases and the transmission electron microscopy detection rate: a systematic review and meta-analysis.Pediatric research · 2017Pooled it
- Assessing Nasal Nitric Oxide in Allergic Rhinitis: A Controversial Biomarker.Medicina (Kaunas, Lithuania) · 2025Article
- Understanding Primary Ciliary Dyskinesia and Other Ciliopathies.The Journal of pediatrics · 2021Review
- Motile ciliopathies.Nature reviews. Disease primers · 2020Review
- The value of nasal nitric oxide measurement in the diagnosis of primary ciliary dyskinesia.Pediatric investigation · 2019Article
- Nasal nitric oxide measurement for primary ciliary dyskinesia diagnosis: The impact of underlying genetic defects on diagnostic accuracy.Pediatric investigation · 2019Article
- Cost-effectiveness analysis of three algorithms for diagnosing primary ciliary dyskinesia: a simulation study.Orphanet journal of rare diseases · 2019Article
- Summary for Clinicians: Diagnosis of Primary Ciliary Dyskinesia.Annals of the American Thoracic Society · 2019Article
- Primary Ciliary Dyskinesia (PCD): A genetic disorder of motile cilia.Translational science of rare diseases · 2019Article
- Proceedings of the 3rd BEAT-PCD Conference and 4th PCD Training School.BMC proceedings · 2018Article
- Primary Ciliary Dyskinesia.Clinics in chest medicine · 2016Review
- Primary ciliary dyskinesia and associated sensory ciliopathies.Expert review of respiratory medicine · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo date, diagnosis of Primary Ciliary Dyskinesia (PCD) remains difficult and challenging. We systematically evaluated the diagnostic performance of nasal Nitric Oxide (nNO) measurement for the detection of PCD, using either velum-closure (VC) or non-velum-closure (non-VC) techniques.
methodsAll major electronic databases were searched from inception until March 2015 using appropriate terms. The sensitivity and specificity of nNO measurement was calculated in PCD patients diagnosed by transmission electron microscopy, high speed video-microscopy or genetic testing. Summary receiver operating characteristic (HSROC) curves were drawn using the parameters of the fitted models.
resultsTwelve studies provided data for 13 different populations, including nine case-control (n = 793) and four prospective cohorts (n = 392). The overall sensitivity of nNO measured by VC techniques was 0.95 (95 % CI 0.91-0.97), while specificity was 0.94 (95 % CI 0.88-0.97). The positive likelihood ratio (LR+) of the test was 15.8 (95 % CI 8.1-30.6), whereas the negative likelihood ratio (LR-) was 0.06 (95 % CI 0.04-0.09). For non-VC techniques, the overall sensitivity of nNO measurement was 0.93 (95 % CI 0.89-0.96) whereas specificity was 0.95 (95 % CI 0.82-0.99). The LR+ of the test was 18.5 (95 % CI 4.6-73.8) whereas the LR- was 0.07 (95 % CI 0.04-0.12).
conclusionsDiagnostic accuracy of nNO measurement both with VC and non-VC maneuvers is high and can be effectively employed in the clinical setting to detect PCD even in young children, thus potentiating early diagnosis. Measurement of nNO merits to be part of a revised diagnostic algorithm with the most efficacious combination of tests to achieve PCD diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials