Evidence map›Paper›PMID 26632405›Full record

ArticleYonsei medical journal2016

Radiologic Outcomes According to Varus Deformity in Minimally Invasive Surgery Total Knee Arthroplasty.

Ju Hyung Yoo, Sang Hoon Park, Chang Dong Han, Hyun Cheol Oh, Jun Young Park, Seung Jin Choi

Open access · goldAbstract read
In one paragraph

Article in Yonsei medical journal, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. [A prospective randomized controlled study of total knee arthroplasty via mini-subvastus and conventional approach].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2018
    Trial
  2. [Expert consensus on clinical pathway for high-conformity total knee arthroplasty through a minimally invasive surgical approach].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Ju Hyung YooDepartment of Orthopedic Surgery, National Health Insurance Service, Ilsan Hospital, Goyang, Korea.
Sang Hoon ParkDepartment of Orthopedic Surgery, National Health Insurance Service, Ilsan Hospital, Goyang, Korea. orthomania@gmail.com.
Chang Dong HanDepartment of Orthopedic Surgery, Yonsei University College of Medicine, Seoul, Korea.
Hyun Cheol OhDepartment of Orthopedic Surgery, National Health Insurance Service, Ilsan Hospital, Goyang, Korea.
Jun Young ParkDepartment of Orthopedic Surgery, National Health Insurance Service, Ilsan Hospital, Goyang, Korea.
Seung Jin ChoiDepartment of Orthopedic Surgery, National Health Insurance Service, Ilsan Hospital, Goyang, Korea.
National Health Insurance Service · KRYonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo identify the accuracy of postoperative implant alignment in minimally invasive surgery total knee arthroplasty (MIS-TKA), based on the degree of varus deformity. MATERIALS AND

methodsThe research examined 627 cases of MIS-TKA from November 2005 to December 2007. The cases were categorized according to the preoperative degree of varus deformity in the knee joint in order to compare the postoperative alignment of the implant: less than 5° varus (Group 1, 351 cases), 5° to less than 10° varus (Group 2, 189 cases), 10° to less than 15° varus (Group 3, 59 cases), and 15° varus or more (Group 4, 28 cases).

resultsOn average, the alignment of the tibial implant was 0.2±1.4°, 0.1±1.3°, 0.1±1.6°, and 0.3±1.7° varus, and the tibiofemoral alignment was 5.2±1.9degrees, 4.7±1.9°, 4.9±1.9°, and 5.1±2.0° valgus for Groups 1, 2, 3, and 4, respectively, in the preoperative stage, indicating no difference between the groups (p>0.05). With respect to the accuracy of the tibial implant alignment, 98.1%, 97.6%, 87.5%, and 86.7% of Groups 1, 2, 3, and 4, respectively, had 0±3° varus angulation, demonstrating a reduced level of accuracy in Groups 3 and 4 (p<0.0001). There was no difference in terms of tibiofemoral alignment, with 83.9%, 82.9%, 85.4%, and 86.7% of each group, respectively, showing 6±3° valgus angulation (p>0.05).

conclusionSatisfactory component alignment was achieved in minimally invasive surgery in total knee arthroplasty, regardless of the degree of varus deformity.

Indexed as

AgedArthroplasty, Replacement, KneeBone AnteversionBone MalalignmentFemaleHumansJoint Deformities, AcquiredKnee JointKnee ProsthesisMaleMiddle AgedMinimally Invasive Surgical ProceduresOsteoarthritis, KneePostoperative PeriodPreoperative PeriodRadiographylower limb alignmentMinimally invasive total knee arthroplastyvarus deformity

Identifiers

PMID26632405
PMCPMC4696958
OpenAlexW2191649329

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.