ArticleMedical physics2015

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.

Wei Wang, Akila N Viswanathan, Antonio L Damato, Yue Chen, Zion Tse, Li Pan, Junichi Tokuda, Ravi T Seethamraju, Charles L Dumoulin, Ehud J Schmidt and 1 more

Open access · bronzeAbstract readEvaluation Study
In one paragraph

Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. MRI-Conditional Eccentric-Tube Injection Needle: Design, Fabrication, and Animal Trial.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2023
    Article
  7. MR-Tracked Deflectable Stylet for Gynecologic Brachytherapy.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2022
    Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. MR-conditional steerable needle robot for intracerebral hemorrhage removal.International journal of computer assisted radiology and surgery · 2019
    Article
  13. MRI-powered biomedical devices.Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy · 2018
    Review
  14. Article
  15. Robotic System for MRI-guided Focal Laser Ablation in the Prostate.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2017
    Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 6 institutions in 1 country.

Wei WangDepartment of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115 and Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115.
Akila N ViswanathanDepartment of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115.
Antonio L DamatoDepartment of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115.
Yue ChenDepartment of Engineering, The University of Georgia, Athens, Georgia 30602.
Zion TseDepartment of Engineering, The University of Georgia, Athens, Georgia 30602.
Li PanSiemens Healthcare USA, Baltimore, Maryland 21287.
Junichi TokudaDepartment of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115.
Ravi T SeethamrajuSiemens Healthcare USA, Boston, Massachusetts 02115.
Charles L DumoulinRadiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio 45229.
Ehud J SchmidtDepartment of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115.
Robert A CormackDepartment of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115.
Brigham and Women's Hospital · USDana-Farber Brigham Cancer Center · USSiemens Healthcare (United States) · USUniversity of Georgia · USCincinnati Children's Hospital Medical Center · USDana-Farber Cancer Institute · US

Funding

Image Guided Therapy Center - Ultrasound-based sensor system for the monitoring of COVID-19 patientsP41EB015898 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI TEMPANY, CLARE M · 2012 to 2021
$18.9M
MR Image Guided Gynecologic BrachytherapyR21CA167800 · NCI · JOHNS HOPKINS UNIVERSITY · PI VISWANATHAN, AKILA · 2013 to 2014
$394k
NCI NIH HHS R21 CA167800NCI NIH HHS R21CA167800NIBIB NIH HHS P41 EB015898NIBIB NIH HHS P41EB015898
6 · The paper itself

Abstract

purposeIn gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT.

methodsThe MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter's trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter's imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT.

resultsThe catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet's orientation deviated from the main magnetic field direction. Fifteen catheters' trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT.

conclusionsThe MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

Indexed as

AdenocarcinomaAlgorithmsArtifactsBrachytherapyCathetersFemaleHumansImaging, Three-DimensionalMagnetic Resonance ImagingPhantoms, ImagingProspective StudiesRadiometryRadiotherapy DosageRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedReproducibility of ResultsWater

Identifiers

PMID26632065
PMCPMC4662673
OpenAlexW2177299365

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.