ArticleEuropean radiology2016
Molecular evaluation of thrombosis using X-ray phase contrast imaging with microbubbles targeted to P-selectin in mice.
Article in European radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 11 citations in OpenAlex.
- Polydopamine-modified dual-ligand nanoparticles as highly effective and targeted magnetic resonance/photoacoustic dual-modality thrombus imaging agents.International journal of nanomedicine · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesX-ray phase contrast imaging (PCI) provides excellent image contrast by utilizing the phase shift. The introduction of microbubbles into tissues can cause a phase shift to make microbubbles visibly identified on PCI. In this study, we assessed the feasibility of targeted microbubble-based PCI for the detection of thrombosis.
methodsThe absorption and phase contrast images of P-selectin-targeted microbubbles (MBP) were obtained and compared in vitro. MBP, control IgG-targeted microbubbles (MBC), and unbound microbubbles (MBU) were tested for binding specificity on thrombi expressing P-selectin. MBP were used as molecular PCI probes to evaluate P-selectin expression in a mouse model of arteriovenous shunt thrombosis that was created using PE tubes in the bypass outside of the mouse body.
resultsPCI clearly showed the microbubbles not viewable via absorption contrast imaging (ACI). In vitro attachment of MBP (91.60 ± 11.63) to thrombi was significantly higher than attachment of MBC (17.80 ± 4.02, P < 0.001) or MBU (9.80 ± 2.59, P < 0.001). In the mouse model of arteriovenous shunt thrombosis, the binding affinity of MBP (15.50 ± 6.25) was significantly greater than that of MBC (0.50 ± 0.84, P < 0.001) or MBU (0.33 ± 0.52, P < 0.001).
conclusionsOur results indicate that molecular PCI may be considered as a novel and promising imaging modality for the investigation of thrombosis. KEY POINTS: • Small thrombi are rarely detected by conventional radiography. • Phase contrast imaging (PCI) provides higher contrast and spatial resolution than conventional radiography. • P-selectin targeted microbubbles detected by PCI may suggest early thrombosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.