Evidence map›Paper›PMID 26625212›Full record

SynthesisThe Cochrane database of systematic reviews2015

Device-modified trabeculectomy for glaucoma.

Xue Wang, Rabeea Khan, Anne Coleman

Open access · greenAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 4 pooled it
6.3field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 4 syntheses or guidelines pooled it, 46 citations in OpenAlex.

  1. Device-modified trabeculectomy for glaucoma.The Cochrane database of systematic reviews · 2023
    Pooled it
  2. Aqueous shunts with mitomycin C versus aqueous shunts alone for glaucoma.The Cochrane database of systematic reviews · 2019
    Pooled it
  3. Aqueous shunts for glaucoma.The Cochrane database of systematic reviews · 2017
    Pooled it
  4. Device-modified trabeculectomy for glaucoma.The Cochrane database of systematic reviews · 2015
    Pooled it
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Observational
  15. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Xue WangDepartment of Epidemiology, Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe Street, Baltimore, Maryland, USA, 21205.
Rabeea Khan
Anne Coleman
Doheny Eye Institute · USJohns Hopkins University · USOlive View-UCLA Medical Center · US

Funding

Comparative Effectiveness Research & the Cochrane Eyes & Vision GroupU01EY020522 · NEI · JOHNS HOPKINS UNIVERSITY · PI DICKERSIN, KAY · 2010 to 2016
$9.2M
Department of HealthNEI NIH HHS U01 EY020522
6 · The paper itself

Abstract

backgroundGlaucoma is an optic neuropathy that leads to vision loss and blindness. It is the second most common cause of irreversible blindness worldwide. The main treatment for glaucoma aims to reduce intraocular pressure (IOP) in order to slow or prevent further vision loss. IOP can be lowered with medications, and laser or incisional surgeries. Trabeculectomy is the most common incisional surgical procedure to treat glaucoma. Device-modified trabeculectomy is intended to improve drainage of the aqueous humor to lower IOP. Trabeculectomy-modifying devices include Ex-PRESS, Ologen, amniotic membrane, expanded polytetrafluoroethylene (E-PTFE) membrane, Gelfilm and others. However, the effectiveness and safety of these devices are uncertain.

objectivesTo assess the relative effectiveness, primarily with respect to IOP control and safety, of the use of different devices as adjuncts to trabeculectomy compared with standard trabeculectomy in eyes with glaucoma. SEARCH

methodsWe searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2014, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2014), EMBASE (January 1980 to December 2014), PubMed (1948 to December 2014), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 22 December 2014. SELECTION CRITERIA: We included randomized controlled trials comparing devices used during trabeculectomy with trabeculectomy alone. We also included studies where antimetabolites were used in either or both treatment groups. DATA COLLECTION AND ANALYSIS: We used standard procedures expected by Cochrane. MAIN

resultsWe found 33 studies that met our inclusion criteria, of which 30 were published as full-length journal articles and three as conference abstracts. Only five studies have been registered. The 33 studies included a total of 1542 participants with glaucoma, and compared five types of devices implanted during trabeculectomy versus trabeculectomy alone. Five studies reported the use of Ex-PRESS (386 participants), eight studies reported the use of Ologen (327 participants), 18 studies reported the use of amniotic membrane (726 participants), one study reported the use of E-PTFE (60 participants), and one study reported the use of Gelfilm (43 participants). These studies were conducted in North America, South America, Europe, Asia, and the Middle East. Planned participant follow-up periods ranged from three months to five years. The studies were reported poorly which limited our ability to judge risk of bias for many domains. Only two studies explicitly masked outcome assessment so, we rated 31 studies at high risk of detection bias.Low-quality evidence from three studies showed that use of Ex-PRESS compared with trabeculectomy alone may be associated with a slightly lower IOP at one year (mean difference (MD) -1.58 mm Hg, 95% confidence interval (CI) -2.74 to -0.42; 165 eyes). Cataract surgery and hyphema may be less frequent in the Ex-PRESS group than in the trabeculectomy-alone group (cataract surgery: risk ratio (RR) 0.32, 95% CI 0.14 to 0.74, 3 studies, low-quality evidence; hyphema: RR 0.33, 95% CI 0.12 to 0.94, 4 studies, low-quality evidence). The effect of whether Ex-PRESS prevents hypotony was uncertain (RR 0.92, 95% CI 0.63 to 1.33, 2 studies, very low-quality evidence). All these studies received funding from the device manufacturer.Very low-quality evidence from five studies suggests that use of Ologen compared with trabeculectomy alone is associated with slightly higher IOP at one year (MD 1.40 mm Hg, 95% CI -0.57 to 3.38; 177 eyes). The effect of Ologen on preventing hypotony was uncertain (RR 0.75, 95% CI 0.47 to 1.19, 5 studies, very low-quality evidence). Differences between the two treatment groups for other reported complications also were inconclusive.Low-quality evidence from nine studies suggests that use of amniotic membrane with trabeculectomy may be associated with lower IOP at one year compared with trabeculectomy alone (MD -3.92 mm Hg, 95% CI -5.41 to -2.42; 356 eyes). Low-quality evidence showed that use of amniotic membrane may prevent adverse events and complications, such as hypotony (RR 0.40, 95% CI 0.17 to 0.94, 5 studies, low-quality evidence).The report from the only E-PTFE study (60 eyes) showed no important differences for postoperative IOP at one year (MD -0.44 mm Hg, 95% CI -1.76 to 0.88) between the trabeculectomy + E-PTFE versus the trabeculectomy-alone groups. Hypotony was the only postoperative complication observed less frequently in the E-PTFE group compared to the trabeculectomy-alone group (RR 0.29, 95% CI 0.11 to 0.77).The one Gelfilm study reported uncertainty in the difference in IOP and complication rates between the two groups at one year; no further data were provided in the study report. AUTHORS'

conclusionsOverall, the use of devices with standard trabeculectomy may help with greater IOP reduction at one-year follow-up than trabeculectomy alone; however, due to potential biases and imprecision in effect estimates, the quality of evidence is low. When we examined outcomes within subgroups based on the type of device used, our findings suggested that the use of an Ex-PRESS device or an amniotic membrane as an adjunct to trabeculectomy may be slightly more effective in reducing IOP at one year after surgery compared with trabeculectomy alone. The evidence that these devices are as safe as trabeculectomy alone is unclear. Due to various limitations in the design and conduct of the included studies, the applicability of this evidence synthesis to other populations or settings is uncertain. Further research is needed to determine the effectiveness and safety of other devices and in subgroup populations, such as people with different types of glaucoma, of various races and ethnicity, and with different lens types (e.g. phakic, pseudophakic).

Indexed as

Glaucoma Drainage ImplantsAmnionBiocompatible MaterialsCollagenGelatinGlaucomaGlycosaminoglycansHumansIntraocular PressurePolytetrafluoroethyleneRandomized Controlled Trials as TopicTrabeculectomyVisual AcuityBiocompatible MaterialsCollagencollagen-glycosaminoglycan copolymerGelatingelatin filmGlycosaminoglycansPolytetrafluoroethylene

Identifiers

PMID26625212
PMCPMC4715269
OpenAlexW1950292328

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked