Evidence map›Paper›PMID 26612076›Full record

ArticleMagnetic resonance imaging2016

Separation of parallel encoded complex-valued slices (SPECS) from a single complex-valued aliased coil image.

Daniel B Rowe, Iain P Bruce, Andrew S Nencka, James S Hyde, Mary C Kociuba

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Autobiography of James S. Hyde.Applied magnetic resonance · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Daniel B RoweDepartment of Mathematics, Statistics, and Computer Science, Marquette University, Milwaukee WI, USA; Department of Biophysics, Medical College of Wisconsin, Milwaukee WI, USA. Electronic address: daniel.rowe@marquette.edu.
Iain P BruceDuke/UNC Brain Imaging and Analysis Center, Duke University, Durham, NC, USA.
Andrew S NenckaDepartment of Biophysics, Medical College of Wisconsin, Milwaukee WI, USA.
James S HydeDepartment of Biophysics, Medical College of Wisconsin, Milwaukee WI, USA.
Mary C KociubaDepartment of Mathematics, Statistics, and Computer Science, Marquette University, Milwaukee WI, USA.
Medical College of Wisconsin · USDuke University · USMarquette University · US

Funding

LOOP GAP RESONATOR COILS FOR MRI AND 31P SPECTROSCOPYR01EB000215 · NIBIB · MEDICAL COLLEGE OF WISCONSIN · PI JESMANOWICZ, ANDRZEJ · 2002 to 2014
$5.8M
Improving f(c)MRI Accuracy by Accounting for the Implications of Data ProcessingR21NS087450 · NINDS · MARQUETTE UNIVERSITY · PI ROWE, DANIEL B · 2014 to 2015
$386k
NIBIB NIH HHS EB000215NIBIB NIH HHS R01 EB000215NINDS NIH HHS NS087450NINDS NIH HHS R21 NS087450
6 · The paper itself

Abstract

purposeAchieving a reduction in scan time with minimal inter-slice signal leakage is one of the significant obstacles in parallel MR imaging. In fMRI, multiband-imaging techniques accelerate data acquisition by simultaneously magnetizing the spatial frequency spectrum of multiple slices. The SPECS model eliminates the consequential inter-slice signal leakage from the slice unaliasing, while maintaining an optimal reduction in scan time and activation statistics in fMRI studies. MATERIALS AND

methodsWhen the combined k-space array is inverse Fourier reconstructed, the resulting aliased image is separated into the un-aliased slices through a least squares estimator. Without the additional spatial information from a phased array of receiver coils, slice separation in SPECS is accomplished with acquired aliased images in shifted FOV aliasing pattern, and a bootstrapping approach of incorporating reference calibration images in an orthogonal Hadamard pattern.

resultThe aliased slices are effectively separated with minimal expense to the spatial and temporal resolution. Functional activation is observed in the motor cortex, as the number of aliased slices is increased, in a bilateral finger tapping fMRI experiment.

conclusionThe SPECS model incorporates calibration reference images together with coefficients of orthogonal polynomials into an un-aliasing estimator to achieve separated images, with virtually no residual artifacts and functional activation detection in separated images.

Indexed as

Magnetic Resonance ImagingAlgorithmsArtifactsBrainBrain MappingCalibrationComputer SimulationEcho-Planar ImagingFourier AnalysisHumansImage EnhancementImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedPhantoms, ImagingfMRIMRIMultibandParallel sliceSimultaneous multi-slice (SMS)SPECS

Identifiers

PMID26612076
PMCPMC4761326
OpenAlexW2216555832

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.