Evidence map›Paper›PMID 26604837›Full record

ReviewMedical devices (Auckland, N.Z.)2015

Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.

Karin Gardner Johnson, Douglas Clark Johnson

Registry-linked trialAbstract readReview
In one paragraph

Review in Medical devices (Auckland, N.Z.), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04327336 (Effectiveness of Noninvasive Ventilation Adjusted Automatically in the Obesity Hypoventilation Syndrome), which is not on this map. Cited by 24 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04327336 nacompletednot on this mapstarted 2020, after this paper: background citation

Effectiveness of Noninvasive Ventilation Adjusted Automatically in the Obesity Hypoventilation Syndrome

TypeinterventionalSponsorSociedad Española de Neumología y Cirugía TorácicaRan2020 to 2023Enrolled200ConditionsChronic Hypercapnic Respiratory Failure, Obesity Hypoventilation SyndromeArmsManual Non invasive ventilation titration, Automatic Non invasive ventilation titration
3 · Its place in the literature

Who cites it

24 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. A novel three-dimensional-printed customized nasal mask for improving CPAP adherence and satisfaction for the treatment of obstructive sleep apnea.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025
    Article
  7. Article
  8. Article
  9. 3D Printing in the Fight Against Covid-19.Medical devices (Auckland, N.Z.) · 2023
    Article
  10. Article
  11. Review
  12. Review
  13. Article
  14. Article
  15. Average volume-assured pressure support vs conventional bilevel pressure support in pediatric nocturnal hypoventilation: a case series.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2021
    Article
  16. Review
  17. Home mechanical ventilation: back to basics.Acute and critical care · 2020
    Article
  18. Ventilators and Ventilatory Modalities.Frontiers in pediatrics · 2020
    Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Karin Gardner JohnsonDepartment of Medicine, Baystate Medical Center, Springfield, MA, USA.
Douglas Clark JohnsonDepartment of Medicine, Baystate Medical Center, Springfield, MA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features.

Indexed as

ASVAVAPSBiPAPCPAPinstrumentationiVAPSpositive pressure respirationtreatment algorithm

Identifiers

PMID26604837
PMCPMC4629962

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.