ArticlePhysiological measurement2015
Method of quantifying 3D strain distribution in skeletal muscle using cine phase contrast MRI.
Article in Physiological measurement, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Investigating the correlation between force output, strains, and pressure for active skeletal muscle contractions.Journal of the mechanical behavior of biomedical materials · 2026Article
- Article
- Strain mapping using compressed sensing accelerated 4D flow MRI-Potential for detecting coactivation in thigh muscles.Frontiers in physiology · 2025Article
- Full-Field Strain Measurements of the Muscle-Tendon Junction Using X-ray Computed Tomography and Digital Volume Correlation.Bioengineering (Basel, Switzerland) · 2024Article
- 3D Muscle Deformation Mapping at Submaximal Isometric Contractions: Applications to Aging Muscle.Frontiers in physiology · 2020Article
- Intramuscular Pressure of Tibialis Anterior Reflects Ankle Torque but Does Not Follow Joint Angle-Torque Relationship.Frontiers in physiology · 2018Article
- Evaluate muscle tension using intramuscular pressure device in rabbit tibialis anterior model for improved tendon transfer surgery.Physiological measurement · 2017Article
- Characterization of three dimensional volumetric strain distribution during passive tension of the human tibialis anterior using Cine Phase Contrast MRI.Journal of biomechanics · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Intramuscular pressure (IMP), a correlate of muscle tension, may fill an important clinical testing void. A barrier to implementing this measure clinically is its non-uniform distribution, which is not fully understood. Pressure is generated by changes in fluid mass and volume, therefore 3D volumetric strain distribution may affect IMP distribution. The purpose of this study was to develop a method for quantifying 3D volumetric strain distribution in the human tibialis anterior (TA) during passive tension using cine phase contrast (CPC) MRI and to assess its accuracy and precision.Five healthy subjects each participated in three data collections. A custom MRI-compatible apparatus repeatedly rotated a subject's ankle between 0° and 26° plantarflexion while CPC MRI data were collected. Additionally, T2-weighted images of the lower leg were collected both before and after the CPC data collection with the ankle stationary at both 0° and 26° plantarflexion for TA muscle segmentation. A 3D hexahedral mesh was generated based on the TA surface before CPC data collection with the ankle at 0° plantarflexion and the node trajectories were tracked using the CPC data. The volumetric strain of each element was quantified.Three tests were employed to assess the measure accuracy and precision. First, to quantify leg position drift, the TA segmentations were compared before and after CPC data collection. The Hawsdorff distance measure (error) was 1.5 ± 0.7 mm. Second, to assess the surface node trajectory accuracy, the deformed mesh surface was compared to the TA segmented at 26° of ankle plantarflexion. This error was 0.6 ± 0.2 mm. Third, the standard deviation of volumetric strain across the three data collections was calculated for each element and subject. The median between-day variability across subjects and mesh elements was 0.06 mm3 mm(-3) (95% confidence interval 0.01 to 0.18 mm3 mm(-3)). Overall the results demonstrated excellent accuracy and precision.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials