Evidence map›Paper›PMID 26584865›Full record

ArticleNeuroImage2016

Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence.

A Alhamud, Paul A Taylor, Andre J W van der Kouwe, Ernesta M Meintjes

Abstract read
In one paragraph

Article in NeuroImage, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed.

  1. Article
  2. Prospective motion correction forMagnetic resonance in medicine · 2025
    Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Real-time shimming with FID navigators.Magnetic resonance in medicine · 2022
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Characterization of BPhysics in medicine and biology · 2020
    Article
  15. Article
  16. Article
  17. Rapid measurement and correction of spatiotemporal BMagnetic resonance in medicine · 2020
    Article
  18. Article
  19. A comparison of static and dynamic ∆BMagnetic resonance in medicine · 2019
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

A AlhamudMRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa. Electronic address: alkk1973@gmail.com.
Paul A TaylorMRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa; African Institute for Mathematical Sciences (AIMS), South Africa.
Andre J W van der KouweAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Department of Radiology, Harvard Medical School, Brookline, MA, USA.
Ernesta M MeintjesMRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, South Africa.

Funding

Scientific and Statistical Computing CoreZICMH002888 · NIMH · NATIONAL INSTITUTE OF MENTAL HEALTH · PI TAYLOR, PAUL · 2009 to 2025
$30.9M
Longitudinal Neuroimaging and Cognitive Study of HIV-Infected ChildrenR01HD071664 · NICHD · MASSACHUSETTS GENERAL HOSPITAL · PI LAUGHTON, BARBARA, MEINTJES, ERNESTA MARIA · 2011 to 2015
$2.4M
Technology development and neuroimaging for 5 year old children with HIV infectioR21MH096559 · NIMH · MASSACHUSETTS GENERAL HOSPITAL · PI LAUGHTON, BARBARA, MEINTJES, ERNESTA MARIA · 2011 to 2012
$287k
Neuroimaging Technology for Pediatric Development Disorders in South AfricaR21AA017410 · NIAAA · MASSACHUSETTS GENERAL HOSPITAL · PI MEINTJES, ERNESTA MARIA, VAN DER KOUWE, ANDRE JAN WILLEM · 2008 to 2009
$254k
NIAAA NIH HHS R21 AA017410NICHD NIH HHS R01 HD071664NIMH NIH HHS R21 MH096559
6 · The paper itself

Abstract

Diffusion tensor imaging (DTI) requires a set of diffusion weighted measurements in order to acquire enough information to characterize local structure. The MRI scanner automatically performs a shimming process by acquiring a field map before the start of a DTI scan. Changes in B0, which can occur throughout the DTI acquisition due to several factors (including heating of the iron shim coils or subject motion), cause significant signal distortions that result in warped diffusion tensor (DT) parameter estimates. In this work we introduce a novel technique to simultaneously measure, report and correct in real time subject motion and changes in B0 field homogeneity, both in and through the imaging plane. This is achieved using double volumetric navigators (DvNav), i.e. a pair of 3D EPI acquisitions, interleaved with the DTI pulse sequence. Changes in the B0 field are evaluated in terms of zero-order (frequency) and first-order (linear gradients) shim. The ability of the DvNav to accurately estimate the shim parameters was first validated in a water phantom. Two healthy subjects were scanned both in the presence and absence of motion using standard, motion corrected (single navigator, vNav), and DvNav DTI sequences. The difference in performance between the proposed 3D EPI field maps and the standard 3D gradient echo field maps of the MRI scanner was also evaluated in a phantom and two healthy subjects. The DvNav sequence was shown to accurately measure and correct changes in B0 following manual adjustments of the scanner's central frequency and the linear shim gradients. Compared to other methods, the DvNav produced DTI results that showed greater spatial overlap with anatomical references, particularly in scans with subject motion. This is largely due to the ability of the DvNav system to correct shim changes and subject motion between each volume acquisition, thus reducing shear distortion.

Indexed as

AdultBrainDiffusion Tensor ImagingEcho-Planar ImagingHumansMaleMovementB0 correctionDiffusion tensor imaging (DTI)Double volumetric navigators (DvNav)Navigated diffusion sequence (vNav)The first-order shim (linear gradients)Zero-order shim (frequency)

Identifiers

PMID26584865
PMCPMC4733594

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked