ArticleNeuroImage2016
Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence.
Article in NeuroImage, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed.
- Improving magnetic field homogeneity in prostate MR imaging and spectroscopy using an add-on local external shim coil array.Magma (New York, N.Y.) · 2026Article
- Prospective motion correction forMagnetic resonance in medicine · 2025Article
- Chemical shift-encoded multishot EPI for navigator-free prostate DWI.Magnetic resonance in medicine · 2025Article
- Dynamic field mapping and distortion correction using single-shot blip-rewound EPI and joint multi-echo reconstruction.Magnetic resonance in medicine · 2024Article
- Advancements in MR hardware systems and magnetic field control: BPsychoradiology · 2024Review
- Prediction of motion induced magnetic fields for human brain MRI at 3 T.Magma (New York, N.Y.) · 2023Article
- Cardiovascular effects on high-resolution 3D multi-shot diffusion MRI of the rhesus macaque brain.Imaging neuroscience (Cambridge, Mass.) · 2023Article
- Water/fat separation for self-navigated diffusion-weighted multishot echo-planar imaging.NMR in biomedicine · 2023Article
- Real-time shimming with FID navigators.Magnetic resonance in medicine · 2022Article
- Data-driven motion-corrected brain MRI incorporating pose-dependent BMagnetic resonance in medicine · 2022Article
- Model-based dynamic off-resonance correction for improved accelerated fMRI in awake behaving nonhuman primates.Magnetic resonance in medicine · 2022Article
- Real-time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T.Magnetic resonance in medicine · 2021Article
- Dynamic distortion correction for functional MRI using FID navigators.Magnetic resonance in medicine · 2021Article
- Characterization of BPhysics in medicine and biology · 2020Article
- Intra-session and inter-subject variability of 3D-FID-MRSI using single-echo volumetric EPI navigators at 3T.Magnetic resonance in medicine · 2020Article
- Improved detection of molecularly targeted iron oxide particles in mouse brain using BMagnetic resonance imaging · 2020Article
- Rapid measurement and correction of spatiotemporal BMagnetic resonance in medicine · 2020Article
- Repeatability and reproducibility of prospective motion- and shim corrected 2D glycoCEST MRI.Quantitative imaging in medicine and surgery · 2019Article
- A comparison of static and dynamic ∆BMagnetic resonance in medicine · 2019Article
- Real-time simultaneous shim and motion measurement and correction in glycoCEST MRI using double volumetric navigators (DvNavs).Magnetic resonance in medicine · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Diffusion tensor imaging (DTI) requires a set of diffusion weighted measurements in order to acquire enough information to characterize local structure. The MRI scanner automatically performs a shimming process by acquiring a field map before the start of a DTI scan. Changes in B0, which can occur throughout the DTI acquisition due to several factors (including heating of the iron shim coils or subject motion), cause significant signal distortions that result in warped diffusion tensor (DT) parameter estimates. In this work we introduce a novel technique to simultaneously measure, report and correct in real time subject motion and changes in B0 field homogeneity, both in and through the imaging plane. This is achieved using double volumetric navigators (DvNav), i.e. a pair of 3D EPI acquisitions, interleaved with the DTI pulse sequence. Changes in the B0 field are evaluated in terms of zero-order (frequency) and first-order (linear gradients) shim. The ability of the DvNav to accurately estimate the shim parameters was first validated in a water phantom. Two healthy subjects were scanned both in the presence and absence of motion using standard, motion corrected (single navigator, vNav), and DvNav DTI sequences. The difference in performance between the proposed 3D EPI field maps and the standard 3D gradient echo field maps of the MRI scanner was also evaluated in a phantom and two healthy subjects. The DvNav sequence was shown to accurately measure and correct changes in B0 following manual adjustments of the scanner's central frequency and the linear shim gradients. Compared to other methods, the DvNav produced DTI results that showed greater spatial overlap with anatomical references, particularly in scans with subject motion. This is largely due to the ability of the DvNav system to correct shim changes and subject motion between each volume acquisition, thus reducing shear distortion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.