Evidence map›Paper›PMID 26583096›Full record

ArticleBioMed research international2015

Biological Behaviour and Enhanced Anticorrosive Performance of the Nitrided Superelastic Ti-23Nb-0.7Ta-2Zr-0.5N Alloy.

Valentina Mitran, Cora Vasilescu, Silviu Iulian Drob, Petre Osiceanu, Jose Maria Calderon-Moreno, Mariana-Cristina Tabirca, Doina-Margareta Gordin, Thierry Gloriant, Anisoara Cimpean

Abstract read
In one paragraph

Article in BioMed research international, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Valentina MitranDepartment of Biochemistry and Molecular Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania.
Cora VasilescuInstitute of Physical Chemistry "Ilie Murgulescu" of Romanian Academy, Splaiul Independentei 202, 060021 Bucharest, Romania.
Silviu Iulian DrobInstitute of Physical Chemistry "Ilie Murgulescu" of Romanian Academy, Splaiul Independentei 202, 060021 Bucharest, Romania.
Petre OsiceanuInstitute of Physical Chemistry "Ilie Murgulescu" of Romanian Academy, Splaiul Independentei 202, 060021 Bucharest, Romania.
Jose Maria Calderon-MorenoInstitute of Physical Chemistry "Ilie Murgulescu" of Romanian Academy, Splaiul Independentei 202, 060021 Bucharest, Romania.
Mariana-Cristina TabircaINSA Rennes, UMR CNRS 6226 Institut des Sciences Chimiques de Rennes, 20 avenue de Buttes de Coëmes, 35708 Rennes Cedex 07, France.
Doina-Margareta GordinINSA Rennes, UMR CNRS 6226 Institut des Sciences Chimiques de Rennes, 20 avenue de Buttes de Coëmes, 35708 Rennes Cedex 07, France.
Thierry GloriantINSA Rennes, UMR CNRS 6226 Institut des Sciences Chimiques de Rennes, 20 avenue de Buttes de Coëmes, 35708 Rennes Cedex 07, France.
Anisoara CimpeanDepartment of Biochemistry and Molecular Biology, University of Bucharest, 91-95 Splaiul Independentei, 050095 Bucharest, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The influence of gas nitriding surface treatment on the superelastic Ti-23Nb-0.7Ta-2Zr-0.5N alloy was evaluated. A thorough characterization of bare and nitrided Ti-based alloy and pure Ti was performed in terms of surface film composition and morphology, electrochemical behaviour, and short term osteoblast response. XPS analysis showed that the nitriding treatment strongly influenced the composition (nitrides and oxynitrides) and surface properties both of the substrate and of the bulk alloy. SEM images revealed that the nitrided surface appears as a similar dotted pattern caused by the formation of N-rich domains coexisting with less nitrided domains, while before treatment only topographical features could be observed. All the electrochemical results confirmed the high chemical stability of the nitride and oxynitride coating and the superiority of the applied treatment. The values of the corrosion parameters ascertained the excellent corrosion resistance of the coated alloy in the real functional conditions from the human body. Cell culture experiments with MG63 osteoblasts demonstrated that the studied biomaterials do not elicit any toxic effects and support cell adhesion and enhanced cell proliferation. Altogether, these data indicate that the nitrided Ti-23Nb-0.7Ta-2Zr-0.5N alloy is the most suitable substrate for application in bone implantology.

Indexed as

Prostheses and ImplantsAlloysBiocompatible MaterialsBone-Implant InterfaceCell ProliferationHumansMaterials TestingOsteoblastsSurface PropertiesTitaniumAlloysBiocompatible MaterialsTitanium

Identifiers

PMID26583096
PMCPMC4637020

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.