Evidence map›Paper›PMID 26578484›Full record

ArticleJournal of medical ultrasonics (2001)2015

Diagnosis of small partial-thickness rotator cuff tears using vibro-acoustography.

Nobuyuki Yamamoto, Randall R Kinnick, Mostafa Fatemi, Takayuki Muraki, John W Sperling, Scott P Steinmann, Robert H Cofield, Eiji Itoi, Kai-Nan An

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Vibroacoustographic System for Tumor Identification.The Yale journal of biology and medicine · 2018
    Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Nobuyuki YamamotoBiomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN, USA.
Randall R KinnickDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN, USA.
Mostafa FatemiDepartment of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN, USA.
Takayuki MurakiBiomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN, USA.
John W SperlingDepartment of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA.
Scott P SteinmannDepartment of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA.
Robert H CofieldDepartment of Orthopedic Surgery, Mayo Clinic College of Medicine, Rochester, MN, USA.
Eiji ItoiDepartment of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai, Japan.
Kai-Nan AnBiomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN, USA. an@mayo.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVibro-acoustography is a new imaging technique based on the dynamic radiation force of ultrasound. The purpose of this study was to apply this new imaging technique to the diagnosis of small partial-thickness rotator cuff tears and to determine how small of tears could be detected with this imaging technique.

methodsSeven supraspinatus tendons excised from embalmed cadavers were used. Three different sizes of partial-thickness bursal-sided tears (1, 3, and 5 mm(3)) were created in each specimen. The intersection of two co-focused ultrasound beams of slightly different frequency was swept across the intended imaging area. The acoustic emission data were collected and used to form and display a vibro-acoustography image of the tendon. Vibro-acoustography images were read by two orthopedic surgeons.

resultsThe rotator cuff tear could be detected by vibro-acoustography in all specimens. The diagnostic concordance rate was 90.5 % and the kappa coefficient value was 0.88, which resulted in a high concordance. The diagnostic concordance rate for the 1 mm tear was 71.3 %, which was low concordance (κ = 0.481), whereas that for the 3 and 5 mm tears was 100 %.

conclusionsWe were able to detect a 3-mm tear by using vibro-acoustography. There is a possibility that this new imaging technique could become a useful imaging tool for the diagnosis of small partial-thickness rotator cuff tears.

Indexed as

Elasticity Imaging TechniquesRotator Cuff InjuriesAgedAged, 80 and overCadaverHumansMiddle AgedRotator CuffDiagnosisRotator cuff tearSmall tearVibro-acoustography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked