Evidence map›Paper›PMID 26578305›Full record

SynthesisKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2017

Locking plate versus non-locking plate in open-wedge high tibial osteotomy: a meta-analysis.

Jae Hwi Han, Hyun Jung Kim, Jae Gwang Song, Jae Hyuk Yang, Ryuichi Nakamura, Daivesh Shah, Young Jee Park, Kyung Wook Nha

Abstract readMeta-Analysis
PubMed Publisher
In one paragraph

Synthesis in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. [Osteotomy close to the knee joint in adults].Orthopadie (Heidelberg, Germany) · 2022
    Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Observational
  17. Article
  18. Surgical anatomy of medial open-wedge high tibial osteotomy: crucial steps and pitfalls.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jae Hwi HanDepartment of Orthopaedic Surgery, Daegu Fatima Hospital, Daegu, Korea.
Hyun Jung KimDepartment of Preventive Medicine, College of Medicine, Institute for Evidence-based Medicine, Korea University, Seoul, Korea.
Jae Gwang SongDepartment of Orthopaedic Surgery, Ilsan Paik Hospital, Inje University, 2240, Daehwa-dong, Ilsan-Segu, Koyang-Si, Ilsan, 411-706, Korea.
Jae Hyuk YangDepartment of Orthopaedic Surgery, Veterans Health Service Medical Center, Seoul, Korea.
Ryuichi NakamuraDepartment of Orthopaedic Surgery, Yawata Medical Center, Komatsu, Japan.
Daivesh ShahDepartment of Orthopaedic Surgery, B J Medical College, New Civil Hospital, Ahmedabad, India.
Young Jee ParkDepartment of Orthopaedic Surgery, Bang-Hwa Hospital, Seoul, Korea.
Kyung Wook NhaDepartment of Orthopaedic Surgery, Ilsan Paik Hospital, Inje University, 2240, Daehwa-dong, Ilsan-Segu, Koyang-Si, Ilsan, 411-706, Korea. kwnhamj@hotmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to conduct a meta-analysis to determine whether the locking plate or non-locking plate results in better opening-wedge high tibial osteotomy (OWHTO) outcomes.

methodsThe MEDLINE, EMBASE, COCHRANE, and KOREAMED register databases were searched for studies. The eligibility criteria for inclusion in the review were studies that compared the locking plate with the non-locking plate for OWHTO, and those that provided clear descriptions of surgical techniques and outcomes. The key outcomes of interest were union rate, correction loss angle, correction loss rate, and full weight-bearing starting point. The statistical software "RevMan" was used in statistical analysis.

resultsFive studies were included in the meta-analysis. Among their reported results, there were no differences in the incidence of union [risk ratio (RR) = 1.01, p = 0.34], non-locking plate was associated with lower incidence of correction maintenance (RR = 1.13, p = 0.0006) and greater angle of correction loss [mean difference (MD) = -2.06, p < 0.00001], and locking plate was associated with a significant improvement in Knee society score and function score (MD = 5.77, p < 0.0001; MD = 7.50, p = 0.0005).

conclusionsLocking plate provides better clinical outcomes and reduced correction loss rates and angles as compared to non-locking plate for fixation with OWHTO. LEVEL OF EVIDENCE: IV.

Indexed as

Bone PlatesHumansKneeMiddle AgedOsteoarthritis, KneeOsteotomyTibiaWeight-BearingKneeMeta-analysisOsteoarthritisOsteonecrosisOsteotomyPlate

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.