Evidence map›Paper›PMID 26573653›Full record

ArticleJournal of medical systems2016

An Intelligent Phonocardiography for Automated Screening of Pediatric Heart Diseases.

Amir A Sepehri, Armen Kocharian, Azin Janani, Arash Gharehbaghi

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07542509 (Digital diagnoSis of Cardiac sOUNd in peDiatric Patients [DI-SOUND Study]), which is not on this map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07542509 recruitingnot on this mapstarted 2024, after this paper: background citation

Digital diagnoSis of Cardiac sOUNd in peDiatric Patients [DI-SOUND Study]

TypeobservationalSponsorIRCCS Azienda Ospedaliero-Universitaria di BolognaRan2024 to 2027Enrolled1,000ConditionsCardiac Disease, Auscultation of Heart, Machine Learning
3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. The first 200 years of cardiac auscultation and future perspectives.Journal of multidisciplinary healthcare · 2019
    Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 3 countries.

Amir A SepehriCAPIS Biomedical Research and Development Department, Mons, Belgium.
Armen KocharianPediatric Cardiovascular, Tehran University of Medical Sciences, Children Medical Center Hospital (Pediatrics Center of Excellence), Tehran, Iran.
Azin JananiAIMS Industrial Group, Biomedical Research and Development Department, Tehran, Iran.
Arash GharehbaghiInnovation, Design and Technology, Mälardalen University, Västerås, Sweden. arash.ghareh.baghi@mdh.se.
Aims Community College · USMälardalen University · SETehran University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a robust device for automated screening of pediatric heart diseases based on our unique processing method in murmur characterization; the Arash-Band method. The present study modifies the Arash-Band method and employs output of the modified method in conjunction with the two other original techniques to extract indicative feature vectors for the screening. The extracted feature vectors are classified by using the support vector machine method. Results show that the proposed modifications significantly enhances performance of the Arash-Band in terms of the both accuracy and sensitivity as the corresponding effect sizes are sufficiently large. The proposed algorithm has been incorporated into an Android-based tablet to constitute an intelligent phonocardiogram with the automatic screening capability. In order to obtain confidence interval of the accuracy and sensitivity, an inferable statistical test is applied on our database containing the phonocardiogram signals recorded from 263 of the referrals to a hospital. The expected value of the accuracy/sensitivity is estimated to be 87.45 % / 87.29 % with a 95 % confidence interval of (80.19 % - 92.47 %) / (76.01 % - 95.78 %) exhibiting superior performance than a pediatric cardiologist who relies on conventional or even computer-assisted auscultation.

Indexed as

AlgorithmsAdolescentChildChild, PreschoolComputers, HandheldElectrocardiographyHeart DiseasesHumansInfantMultimodal ImagingPhonocardiographyReproducibility of ResultsSignal Processing, Computer-AssistedHeart murmurHeart soundIntelligent phonocardiogramPediatric heart diseasesPhonocardiogram

Identifiers

PMID26573653
OpenAlexW2198753695

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.