Evidence map›Paper›PMID 26566429›Full record

ArticleWorld journal of gastrointestinal endoscopy2015

Optimization of the generator settings for endobiliary radiofrequency ablation.

Maximilien Barret, Sarah Leblanc, Ariane Vienne, Alexandre Rouquette, Frederic Beuvon, Stanislas Chaussade, Frederic Prat

Open access · hybridAbstract read
In one paragraph

Article in World journal of gastrointestinal endoscopy, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Maximilien BarretMaximilien Barret, Sarah Leblanc, Ariane Vienne, Stanislas Chaussade, Frederic Prat, Department of Gastroenterology, Cochin Hospital, 75014 Paris, France.
Sarah LeblancMaximilien Barret, Sarah Leblanc, Ariane Vienne, Stanislas Chaussade, Frederic Prat, Department of Gastroenterology, Cochin Hospital, 75014 Paris, France.
Ariane VienneMaximilien Barret, Sarah Leblanc, Ariane Vienne, Stanislas Chaussade, Frederic Prat, Department of Gastroenterology, Cochin Hospital, 75014 Paris, France.
Alexandre RouquetteMaximilien Barret, Sarah Leblanc, Ariane Vienne, Stanislas Chaussade, Frederic Prat, Department of Gastroenterology, Cochin Hospital, 75014 Paris, France.
Frederic BeuvonMaximilien Barret, Sarah Leblanc, Ariane Vienne, Stanislas Chaussade, Frederic Prat, Department of Gastroenterology, Cochin Hospital, 75014 Paris, France.
Stanislas ChaussadeMaximilien Barret, Sarah Leblanc, Ariane Vienne, Stanislas Chaussade, Frederic Prat, Department of Gastroenterology, Cochin Hospital, 75014 Paris, France.
Frederic PratMaximilien Barret, Sarah Leblanc, Ariane Vienne, Stanislas Chaussade, Frederic Prat, Department of Gastroenterology, Cochin Hospital, 75014 Paris, France.
Délégation Paris 5 · FRCreative Research Enterprises (United States) · USHôpital Cochin · FRUniversité Paris Cité · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo determine the optimal generator settings for endobiliary radiofrequency ablation.

methodsEndobiliary radiofrequency ablation was performed in live swine on the ampulla of Vater, the common bile duct and in the hepatic parenchyma. Radiofrequency ablation time, "effect", and power were allowed to vary. The animals were sacrificed two hours after the procedure. Histopathological assessment of the depth of the thermal lesions was performed.

resultsTwenty-five radiofrequency bursts were applied in three swine. In the ampulla of Vater (n = 3), necrosis of the duodenal wall was observed starting with an effect set at 8, power output set at 10 W, and a 30 s shot duration, whereas superficial mucosal damage of up to 350 μm in depth was recorded for an effect set at 8, power output set at 6 W and a 30 s shot duration. In the common bile duct (n = 4), a 1070 μm, safe and efficient ablation was obtained for an effect set at 8, a power output of 8 W, and an ablation time of 30 s. Within the hepatic parenchyma (n = 18), the depth of tissue damage varied from 1620 μm (effect = 8, power = 10 W, ablation time = 15 s) to 4480 μm (effect = 8, power = 8 W, ablation time = 90 s).

conclusionThe duration of the catheter application appeared to be the most important parameter influencing the depth of the thermal injury during endobiliary radiofrequency ablation. In healthy swine, the currently recommended settings of the generator may induce severe, supratherapeutic tissue damage in the biliary tree, especially in the high-risk area of the ampulla of Vater.

Indexed as

Ampullary tumorBiliary strictureEndobiliary radiofrequency ablationEndoscopic retrograde cholangio-pancreatography

Identifiers

PMID26566429
PMCPMC4639744
OpenAlexW2192120556

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.