Evidence map›Paper›PMID 26564383›Full record

ArticleJournal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine2016

Pressure-Relief Features of Fixed and Autotitrating Continuous Positive Airway Pressure May Impair Their Efficacy: Evaluation with a Respiratory Bench Model.

Kaixian Zhu, Sami Aouf, Gabriel Roisman, Pierre Escourrou

Open access · bronzeAbstract read
In one paragraph

Article in Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Safety principles of lowering inspiratory pressure.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2026
    Article
  3. Article
  4. The influence of an innovative inspiratory pressure relief accessory on continuous positive airway pressure profiles in a laboratory bench setting.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025
    Article
  5. Article
  6. Article
  7. APAP, BPAP, CPAP, and New Modes of Positive Airway Pressure Therapy.Advances in experimental medicine and biology · 2022
    Review
  8. Use of the WatchPAT to detect occult residual sleep-disordered breathing in patients on CPAP for obstructive sleep apnea.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2020
    Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Kaixian ZhuAir Liquide Healthcare, Gentilly, France.
Sami AoufAir Liquide Healthcare, Gentilly, France.
Gabriel RoismanSleep Disorders Center, AP-HP Antoine-Béclère Hospital, Clamart, France.
Pierre EscourrouSleep Disorders Center, AP-HP Antoine-Béclère Hospital, Clamart, France.
Université Paris-Sud · FRAir Liquide (France) · FRAssistance Publique – Hôpitaux de Paris · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

objectivesPressure-relief features are aimed at improving the patient's comfort during continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea. The objective of this study was to determine the effect of these therapy features on fixed CPAP and autotitrating CPAP (APAP) treatment efficacy.

methodsSeven pressure-relief features applied by three CPAP devices were included in our study (Remstar Auto: C-Flex 3, C-Flex+ 3, A-Flex 3, P-Flex; AirSense 10: EPR 3; Prisma 20A: SoftPAP 2 and 3). In fixed CPAP, the devices were subjected to a 10-min bench-simulated obstructive apnea sequence (initial apnea-hypopnea index, AHI = 60/h) with and without pressure-relief features. In APAP, the sequence was lengthened to 4.2 h (initial AHI = 58.6/h). The residual AHI and mean/median pressure were compared with and without pressure-relief features.

resultsCompared to conventional CPAP, where pressure was adjusted to be just sufficient to control the simulated obstructive events, C-Flex+ 3, P-Flex, and EPR 3 failed to normalize the breathing flow and did not reduce the AHI. The mean pressures with the three features, respectively, were 1.8, 2.6, and 2.6 cmH2O lower than the conventional CPAP. Compared to conventional APAP, similar levels of control were observed with pressure-relief features, apart from P-Flex where the delivered mean pressure was lower and residual AHI greater. The device-reported mean/median pressures in APAP with A-Flex 3, P-Flex, EPR 3, and SoftPAP 3 were higher than that measured on the bench.

conclusionsPressure-relief features may attenuate CPAP efficacy if not adjusted for at the time of their introduction. In clinical practice, efficacy can be ensured by increasing the therapeutic pressure delivered by fixed CPAP or by enabling the pressure-relief features prior to initial pressure titration. Device-reported pressures in APAP devices with pressure relief activated may overstate delivered pressures.

Indexed as

Models, BiologicalContinuous Positive Airway PressureEquipment DesignPressureSleep Apnea, ObstructiveTreatment Outcomebench testCPAP treatmentpressure-relief features

Identifiers

PMID26564383
PMCPMC4773618
OpenAlexW2413288381

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.