Evidence map›Paper›PMID 26563510›Full record

ArticleSurgical endoscopy2016

Effect of nanostructured thin film on minimally invasive surgery devices applications: characterization, cell cytotoxicity evaluation and an animal study in rat.

Keng-Liang Ou, Chao-Chia Weng, Erwan Sugiatno, Muhammad Ruslin, Yun-Ho Lin, Han-Yi Cheng

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Keng-Liang OuSchool of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, 110, Taiwan.
Chao-Chia WengSchool of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, 110, Taiwan.
Erwan SugiatnoResearch Center for Biomedical Devices and Prototyping Production, Taipei Medical University, Taipei, 110, Taiwan.
Muhammad RuslinResearch Center for Biomedical Devices and Prototyping Production, Taipei Medical University, Taipei, 110, Taiwan.
Yun-Ho LinDepartment of Pathology, Taipei Medical University, Taipei, 110, Taiwan. kevinyhl@tmu.edu.tw.
Han-Yi ChengResearch Center for Biomedical Devices and Prototyping Production, Taipei Medical University, Taipei, 110, Taiwan. chytmu@gmail.com.
Taipei Medical University · TWTaipei Medical University-Shuang Ho Hospital · TWUniversitas Gadjah Mada · ID

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMinimally invasive surgery is performed using an endoscope and other instruments including the electrosurgical units. However, concerns including surgical smoke, tissue sticking and thermal injury are remaining in electrosurgery.

aimsAccordingly, a newly developed electrosurgical electrode coating with hydrogenated Cu-incorporated diamond-like carbon (DLC-Cu) film is purposed to improve the instrument performance.

methodsThe morphologies of DLC-Cu surfaces were characterized using transmission electron microscopy, scanning electron microscopy and atomic force microscopy. In this study, lesions were made on the liver lobes of adult rats, using a monopolar electrosurgical unit equipped with untreated stainless steel electrodes or treated-electrodes. Animals were killed for evaluations at 0, 3, 7 and 28 days postoperatively.

resultsTreated-electrodes generate less sticking tissues and adhesive blood cells. Thermography revealed that the surgical temperature in liver tissue from the treated-electrode was significantly lower than the untreated-electrode. Total injury area of livers treated with treated-electrodes was significantly smaller than the untreated-electrodes treatment. Moreover, treated-electrodes caused a relatively smaller area of lateral thermal injury, a smaller area of fibrotic tissue and a faster process of remodeling than the untreated-electrodes. Western blot analysis showed that rats treated with treated-electrode expressed lower levels of NF-κB, caspase-3 and MMP-9 than untreated-electrode. Immunofluorescence staining for caspase-3 revealed that the untreated-electrode caused more serious injury.

conclusionsThis study reveals that the plating of electrodes with hydrogenated Cu-incorporated diamond-like carbon film is an efficient method for improving the performance of electrosurgical units, and should benefit wound remodeling. However, more tests must be carried out to confirm these promising findings in human patients.

Indexed as

ElectrodesNanostructuresAnimalsBlotting, WesternBurnsCarbonCaspase 3Coated Materials, BiocompatibleCopperDisease Models, AnimalElectrosurgeryLiverMatrix Metalloproteinase 9Microscopy, Electron, ScanningMicroscopy, Electron, TransmissionMinimally Invasive Surgical ProceduresCarbonCaspase 3Coated Materials, BiocompatibleCopperMatrix Metalloproteinase 9Mmp9 protein, ratNF-kappa BStainless SteelBiomedical coatingIn vivo testMinimally invasive surgeryMonopolar electrosurgeryThermal injuryTissue sticking

Identifiers

PMID26563510
OpenAlexW2141365664

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked