Evidence map›Paper›PMID 26563101›Full record

ArticleAnnals of biomedical engineering2016

Mapping 3D Strains with Ultrasound Speckle Tracking: Method Validation and Initial Results in Porcine Scleral Inflation.

Benjamin Cruz Perez, Elias Pavlatos, Hugh J Morris, Hong Chen, Xueliang Pan, Richard T Hart, Jun Liu

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Article
  2. Article
  3. Biomechanical Correlations Between the Cornea and the Optic Nerve Head.Investigative ophthalmology & visual science · 2024
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Scleral structure and biomechanics.Progress in retinal and eye research · 2020
    Review
  12. Article
  13. Article
  14. Article
  15. 3D Characterization of corneal deformation using ultrasound speckle tracking.Journal of innovative optical health sciences · 2017
    Article
  16. Article
  17. Article
  18. Whole-globe biomechanics using high-field MRI.Experimental eye research · 2017
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Benjamin Cruz PerezDepartment of Biomedical Engineering, The Ohio State University, Jun Liu, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH, USA.
Elias PavlatosDepartment of Biomedical Engineering, The Ohio State University, Jun Liu, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH, USA.
Hugh J MorrisDepartment of Biomedical Engineering, The Ohio State University, Jun Liu, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH, USA.
Hong ChenDepartment of Biomedical Engineering, The Ohio State University, Jun Liu, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH, USA.
Xueliang PanCenter for Biostatistics, The Ohio State University, Columbus, OH, USA.
Richard T HartDepartment of Biomedical Engineering, The Ohio State University, Jun Liu, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH, USA.
Jun LiuDepartment of Biomedical Engineering, The Ohio State University, Jun Liu, 270 Bevis Hall, 1080 Carmack Rd, Columbus, OH, USA. liu.314@osu.edu.

Funding

Corneoscleral Biomechanics and Intraocular PressureR01EY020929 · NEI · OHIO STATE UNIVERSITY · PI LIU, JUN · 2011 to 2014
$1.3M
NEI NIH HHS R01 EY020929
6 · The paper itself

Abstract

This study aimed to develop and validate a high frequency ultrasound method for measuring distributive, 3D strains in the sclera during elevations of intraocular pressure. A 3D cross-correlation based speckle-tracking algorithm was implemented to compute the 3D displacement vector and strain tensor at each tracking point. Simulated ultrasound radiofrequency data from a sclera-like structure at undeformed and deformed states with known strains were used to evaluate the accuracy and signal-to-noise ratio (SNR) of strain estimation. An experimental high frequency ultrasound (55 MHz) system was built to acquire 3D scans of porcine eyes inflated from 15 to 17 and then 19 mmHg. Simulations confirmed good strain estimation accuracy and SNR (e.g., the axial strains had less than 4.5% error with SNRs greater than 16.5 for strains from 0.005 to 0.05). Experimental data in porcine eyes showed increasing tensile, compressive, and shear strains in the posterior sclera during inflation, with a volume ratio close to one suggesting near-incompressibility. This study established the feasibility of using high frequency ultrasound speckle tracking for measuring 3D tissue strains and its potential to characterize physiological deformations in the posterior eye.

Indexed as

Intraocular PressureAnimalsScleraSignal-To-Noise RatioSwineTensile StrengthUltrasonography3D strainsInflation testingPeripapillary scleraScleral biomechanicsUltrasound speckle tracking

Identifiers

PMID26563101
PMCPMC4865453

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.