Accurate determination of segmented X-ray detector geometry.

Oleksandr Yefanov, Valerio Mariani, Cornelius Gati, Thomas A White, Henry N Chapman, Anton Barty

Abstract readEvaluation Study
In one paragraph

Article in Optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 59 papers.

0numbers the graph read from it
0cells of the map it votes in
59citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

59 citing papers in PubMed.

  1. Radiation damage in serial femtosecond crystallography studied in hemoglobin.Acta crystallographica. Section D, Structural biology · 2026
    Article
  2. Article
  3. Detector alignment for X-ray crystallography usingJournal of applied crystallography · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. A snapshot love story: what serial crystallography has done and will do for us.Acta crystallographica. Section D, Structural biology · 2024
    Review
  10. Article
  11. Article
  12. SARS-CoV-2 MNature communications · 2024
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Guide to serial synchrotron crystallography.Current research in structural biology · 2024
    Review
  19. Structure of theProceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Oleksandr Yefanov
Valerio Mariani
Cornelius Gati
Thomas A White
Henry N Chapman
Anton Barty

Funding

ZWITTERION SURFACTANT DDMAB FOR IMPROV STABIL OF PROTEINP41RR001209 · NCRR · STANFORD UNIVERSITY · PI GONZALEZ, ANA M · 1985 to 2011
$38.9M
X-ray Absorption Spectroscopy (XAS) pp.711-759P41GM103393 · NIGMS · STANFORD UNIVERSITY · PI HODGSON, KEITH O · 2012 to 2019
$30.6M
Center for the Rational Design of Membrane Protein CrystallographyU54GM094599 · NIGMS · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI FROMME, PETRA · 2010 to 2014
$6.8M
Femtosecond nano-crystallography of membrane proteinsR01GM095583 · NIGMS · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI FROMME, PETRA · 2010 to 2023
$4.3M
Tracking conformational states in enzyme catalysts using correlated X-ray scatterR01GM097463 · NIGMS · STANFORD UNIVERSITY · PI DONIACH, SEBASTIAN · 2012 to 2015
$1.7M
NCRR NIH HHS P41 RR001209NCRR NIH HHS P41RR001209NIGMS NIH HHS P41 GM103393NIGMS NIH HHS P41GM103393NIGMS NIH HHS R01 GM095583NIGMS NIH HHS R01 GM097463NIGMS NIH HHS U54 GM094599
6 · The paper itself

Abstract

Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. We show that the refined detector geometry greatly improves the results of experiments.

Indexed as

AlgorithmsCalibrationCrystallography, X-RayEquipment DesignEquipment Failure AnalysisRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID26561117
PMCPMC4646514

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.