Evidence map›Paper›PMID 26558277›Full record

ArticleBioMed research international2015

Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit.

Elena Bergon-Sendin, Carmen Perez-Grande, David Lora-Pablos, Javier De la Cruz Bertolo, María Teresa Moral-Pumarega, Gerardo Bustos-Lozano, Carmen Rosa Pallas-Alonso

Abstract read
In one paragraph

Article in BioMed research international, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Elena Bergon-SendinDepartment of Neonatology, 12 de Octubre University Hospital, Biomedical Research Institute i+12, Madrid, Spain.
Carmen Perez-GrandeDepartment of Neonatology, 12 de Octubre University Hospital, Biomedical Research Institute i+12, Madrid, Spain.
David Lora-PablosDepartment of Neonatology, 12 de Octubre University Hospital, Biomedical Research Institute i+12, Madrid, Spain.
Javier De la Cruz BertoloDepartment of Neonatology, 12 de Octubre University Hospital, Biomedical Research Institute i+12, Madrid, Spain.
María Teresa Moral-PumaregaDepartment of Neonatology, 12 de Octubre University Hospital, Biomedical Research Institute i+12, Madrid, Spain.
Gerardo Bustos-LozanoDepartment of Neonatology, 12 de Octubre University Hospital, Biomedical Research Institute i+12, Madrid, Spain.
Carmen Rosa Pallas-AlonsoDepartment of Neonatology, 12 de Octubre University Hospital, Biomedical Research Institute i+12, Madrid, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRandom safety audits (RSAs) are a safety tool but have not been widely used in hospitals.

objectivesTo determine the frequency of proper use of equipment safety mechanisms in relation to monitoring and mechanical ventilation by performing RSAs. The study also determined whether factors related to the patient, time period, or characteristics of the area of admission influenced how the device safety systems were used.

methodsA prospective observational study was conducted in a level III-C Neonatal Intensive Care Unit (NICU) during 2012. 87 days were randomly selected. Appropriate overall use was defined when all evaluated variables were correctly programmed in the audited device.

resultsA total of 383 monitor and ventilator audits were performed. The Kappa coefficient of interobserver agreement was 0.93. The rate of appropriate overall use of the monitors and respiratory support equipment was 33.68%. Significant differences were found with improved usage during weekends, OR 1.85 (1.12-3.06, p = 0.01), and during the late shift (3 pm to 10 pm), OR 1.59 (1.03-2.4, p = 0.03).

conclusionsEquipment safety systems of monitors and ventilators are not properly used. To improve patient safety, we should identify which alarms are really needed and where the difficulties lie for the correct alarm programming.

Indexed as

Clinical AuditHumansInfant, NewbornIntensive Care Units, NeonatalMonitoring, PhysiologicPatient SafetyProspective StudiesRespiration, Artificial

Identifiers

PMID26558277
PMCPMC4628988

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.