Novel Method to Track Soft Tissue Deformation by Micro-Computed Tomography: Application to the Mitral Valve.

Eric L Pierce, Charles H Bloodworth, Ajay Naran, Thomas F Easley, Morten O Jensen, Ajit P Yoganathan

Open access · greenAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Eric L PierceWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA.
Charles H BloodworthWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA.
Ajay NaranWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA.
Thomas F EasleyWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA.
Morten O JensenWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA.
Ajit P YoganathanWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle NW, Suite 200, Atlanta, GA, 30313, USA. ajit.yoganathan@bme.gatech.edu.
Georgia Institute of Technology · USThe Wallace H. Coulter Department of Biomedical Engineering · US

Funding

Remodeling potential of the mitral valve following surgical repairR01HL119297 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI GORMAN, JOSEPH H, SACKS, MICHAEL S · 2013 to 2017
$6.6M
NHLBI NIH HHS R01 HL119297
6 · The paper itself

Abstract

Increasing availability of micro-computed tomography (µCT) as a structural imaging gold-standard is bringing unprecedented geometric detail to soft tissue modeling. However, the utility of these advances is severely hindered without analogous enhancement to the associated kinematic detail. To this end, labeling and following discrete points on a tissue across various deformation states is a well-established approach. Still, existing techniques suffer limitations when applied to complex geometries and large deformations and strains. Therefore, we herein developed a non-destructive system for applying fiducial markers (minimum diameter: 500 µm) to soft tissue and tracking them through multiple loading conditions by µCT. Using a novel applicator to minimize adhesive usage, four distinct marker materials were resolvable from both tissue and one another, without image artifacts. No impact on tissue stiffness was observed. µCT addressed accuracy limitations of stereophotogrammetry (inter-method positional error 1.2 ± 0.3 mm, given marker diameter 1.9 ± 0.1 mm). Marker application to ovine mitral valves revealed leaflet Almansi areal strains (45 ± 4%) closely matching literature values, and provided radiographic access to previously inaccessible regions, such as the leaflet coaptation zone. This system may meaningfully support mechanical characterization of numerous tissues or biomaterials, as well as tissue-device interaction studies for regulatory standards purposes.

Indexed as

AnimalsMitral ValveX-Ray MicrotomographyCardiovascularEx vivoImagingMaterial propertiesMicro-computed tomographySimulation

Identifiers

PMID26553575
PMCPMC4861692
OpenAlexW2122093264

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.