Evidence map›Paper›PMID 26552720›Full record

ArticleScientific reports2015

Peptide Functionalized Gold Nanorods for the Sensitive Detection of a Cardiac Biomarker Using Plasmonic Paper Devices.

Sirimuvva Tadepalli, Zhifeng Kuang, Qisheng Jiang, Keng-Ku Liu, Marilee A Fisher, Jeremiah J Morrissey, Evan D Kharasch, Joseph M Slocik, Rajesh R Naik, Srikanth Singamaneni

Abstract read
In one paragraph

Article in Scientific reports, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed.

  1. Article
  2. Article
  3. Two-Dimensional MoSACS applied materials & interfaces · 2025
    Article
  4. Paper-Based Sensors: Fantasy or Reality?Nanomaterials (Basel, Switzerland) · 2025
    Review
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Hybrid Plasmonic Fiber-Optic Sensors.Sensors (Basel, Switzerland) · 2020
    Review
  17. Article
  18. Article
  19. Review
  20. Point of care testing for infectious diseases.Clinica chimica acta; international journal of clinical chemistry · 2019
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Sirimuvva TadepalliInstitute of Material Science and Engineering and Department of Mechanical Engineering and Material Science, Washington University in St. Louis, St. Louis, MO, 63130, USA.
Zhifeng KuangSoft Matter Materials Branch, Materials and Manufacturing Directorate, Wright Patterson Air Force Base, Dayton, OH 45433, USA.
Qisheng JiangInstitute of Material Science and Engineering and Department of Mechanical Engineering and Material Science, Washington University in St. Louis, St. Louis, MO, 63130, USA.
Keng-Ku LiuInstitute of Material Science and Engineering and Department of Mechanical Engineering and Material Science, Washington University in St. Louis, St. Louis, MO, 63130, USA.
Marilee A FisherDepartment of Anesthesiology, Division of Clinical and Translational Research, Washington University in St. Louis, St. Louis, MO 63110, USA.
Jeremiah J MorrisseyDepartment of Anesthesiology, Division of Clinical and Translational Research, Washington University in St. Louis, St. Louis, MO 63110, USA.
Evan D KharaschDepartment of Anesthesiology, Division of Clinical and Translational Research, Washington University in St. Louis, St. Louis, MO 63110, USA.
Joseph M SlocikSoft Matter Materials Branch, Materials and Manufacturing Directorate, Wright Patterson Air Force Base, Dayton, OH 45433, USA.
Rajesh R NaikSoft Matter Materials Branch, Materials and Manufacturing Directorate, Wright Patterson Air Force Base, Dayton, OH 45433, USA.
Srikanth SingamaneniInstitute of Material Science and Engineering and Department of Mechanical Engineering and Material Science, Washington University in St. Louis, St. Louis, MO, 63130, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The sensitivity of localized surface plasmon resonance (LSPR) of metal nanostructures to adsorbates lends itself to a powerful class of label-free biosensors. Optical properties of plasmonic nanostructures are dependent on the geometrical features and the local dielectric environment. The exponential decay of the sensitivity from the surface of the plasmonic nanotransducer calls for the careful consideration in its design with particular attention to the size of the recognition and analyte layers. In this study, we demonstrate that short peptides as biorecognition elements (BRE) compared to larger antibodies as target capture agents offer several advantages. Using a bioplasmonic paper device (BPD), we demonstrate the selective and sensitive detection of the cardiac biomarker troponin I (cTnI). The smaller sized peptide provides higher sensitivity and a lower detection limit using a BPD. Furthermore, the excellent shelf-life and thermal stability of peptide-based LSPR sensors, which precludes the need for special storage conditions, makes it ideal for use in resource-limited settings.

Indexed as

Amino Acid SequenceBiomarkersBiosensing TechniquesGoldHumansNanotubesPaperPeptidesProtein BindingSurface Plasmon ResonanceSweatTroponin IBiomarkersGoldPeptidesTroponin I

Identifiers

PMID26552720
PMCPMC4639779

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.