Evidence map›Paper›PMID 26552388›Full record

ArticleJournal of the American Society for Mass Spectrometry2016

Distance-of-Flight Mass Spectrometry with IonCCD Detection and an Inductively Coupled Plasma Source.

Elise A Dennis, Steven J Ray, Christie G Enke, Alexander W Gundlach-Graham, Charles J Barinaga, David W Koppenaal, Gary M Hieftje

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Distance-of-Flight Mass Spectrometry: What, Why, and How?Journal of the American Society for Mass Spectrometry · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Elise A DennisDepartment of Chemistry, Indiana University, Bloomington, IN, 47405, USA.
Steven J RayDepartment of Chemistry, Indiana University, Bloomington, IN, 47405, USA.
Christie G EnkeDepartment of Chemistry and Chemical Biology, University of New Mexico, Albuquerque, NM, 87131, USA.
Alexander W Gundlach-GrahamDepartment of Chemistry and Applied Biosciences, ETH Zurich, 8093, Zurich, Switzerland.
Charles J BarinagaPacific Northwest National Laboratory, Richland, WA, 99352, USA.
David W KoppenaalPacific Northwest National Laboratory, Richland, WA, 99352, USA.
Gary M HieftjeDepartment of Chemistry, Indiana University, Bloomington, IN, 47405, USA. hieftje@indiana.edu.
Indiana University Bloomington · USPacific Northwest National Laboratory · USETH Zurich · CHUniversity of New Mexico · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Distance-of-flight mass spectrometry (DOFMS) is demonstrated for the first time with a commercially available ion detector-the IonCCD camera. Because DOFMS is a velocity-based MS technique that provides spatially dispersive, simultaneous mass spectrometry, a position-sensitive ion detector is needed for mass-spectral collection. The IonCCD camera is a 5.1-cm long, 1-D array that is capable of simultaneous, multichannel ion detection along a focal plane, which makes it an attractive option for DOFMS. In the current study, the IonCCD camera is evaluated for DOFMS with an inductively coupled plasma (ICP) ionization source over a relatively short field-free mass-separation distance of 25.3-30.4 cm. The combination of ICP-DOFMS and the IonCCD detector results in a mass-spectral resolving power (FWHM) of approximately 900 and isotope-ratio precision equivalent to or slightly better than current ICP-TOFMS systems. The measured isotope-ratio precision in % relative standard deviation (%RSD) was ≥0.008%RSD for nonconsecutive isotopes at 10-ppm concentration (near the ion-signal saturation point) and ≥0.02%RSD for all isotopes at 1-ppm. Results of DOFMS with the IonCCD camera are also compared with those of two previously characterized detection setups.

Indexed as

Distance-of-flightInductively coupled plasmaInstrumentationIonCCD camera

Identifiers

PMID26552388
OpenAlexW2151366687

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.