Evidence map›Paper›PMID 26541726›Full record

ArticleSurgical endoscopy2016

Sutureless onlay hernia repair: a review of 97 patients.

Charles P Shahan, Nathaniel F Stoikes, David L Webb, Guy R Voeller

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 24 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. The 4 Principles of Complex Abdominal Wall Reconstruction.Plastic and reconstructive surgery. Global open · 2019
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Charles P ShahanDepartment of Surgery, University of Tennessee Health Science Center, 910 Madison Ave, 2nd Floor, Memphis, TN, 38163, USA. cshahan@uthsc.edu.
Nathaniel F StoikesDepartment of Surgery, University of Tennessee Health Science Center, 910 Madison Ave, 2nd Floor, Memphis, TN, 38163, USA.
David L WebbDepartment of Surgery, University of Tennessee Health Science Center, 910 Madison Ave, 2nd Floor, Memphis, TN, 38163, USA.
Guy R VoellerDepartment of Surgery, University of Tennessee Health Science Center, 910 Madison Ave, 2nd Floor, Memphis, TN, 38163, USA.
University of Tennessee Health Science Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRepair of large ventral/incisional (V/I) hernias is a common problem. Outside of recurrence, other factors such as wound complications and mesh infection can create significant morbidity. Chevrel described the premuscular repair and later modified it by using glue over the midline closure. We previously described our onlay technique using fibrin glue alone in a small case series. The aim of this study is to review the largest case series of sutureless onlay V/I hernia repair whereby mesh is fixated with fibrin glue alone for complex ventral hernias, and how the technique has evolved.

methodsAll patients who underwent onlay V/I hernia repair over a 3-year period were reviewed. Patient demographics, operative details, complications, and follow-up were reviewed.

resultsIn total, 97 patients were included. 54.6 % were female, with a mean age of 57.3 years. Mean BMI was 32.2. 23(23.7 %) patients had diabetes. 90 (92.8 %) of the operations were for incisional hernias, 3 (3.1 %) primary ventral hernias, 2 (2.1 %) flank hernias, and 2 (2 %) complex abdominal wall reconstruction. 88 (90.7 %) of the cases were performed on an elective basis. 77 (77.3 %) cases were classified as clean, 21 (21.6 %) clean-contaminated, and 1 (1.0 %) contaminated. The mean defect size was 150 cm(2). Mean follow-up was 386 days, and maximum was 3.1 years. There were 21 (21.6 %) seromas, 4 (4.1 %) wound infections, 7 (7.4 %) had skin necrosis, and 9 (9.3 %) required re-operation due to a complication. At 3 years, there have been no recurrences or mesh explants.

conclusionsThe sutureless onlay V/I hernia repair with fibrin glue fixation has proven to be durable with a comparable complication profile to other techniques. The most common sequela, seroma, is easily managed in the outpatient setting. This sutureless technique is an effective option for onlay hernia repair that may provide several advantages over traditional suture techniques.

Indexed as

Surgical MeshElective Surgical ProceduresFemaleFibrin Tissue AdhesiveHernia, VentralHerniorrhaphyHumansIncisional HerniaMaleMiddle AgedPostoperative ComplicationsRecurrenceReoperationSeromaSurgical Wound InfectionSuture TechniquesFibrin Tissue AdhesiveAbdominal wallFibrin glueHerniaOnlay

Identifiers

PMID26541726
OpenAlexW2231050079

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked