Evidence map›Paper›PMID 26537203›Full record

ArticleActa biomaterialia2016

Porous, Dexamethasone-loaded polyurethane coatings extend performance window of implantable glucose sensors in vivo.

Suzana G Vallejo-Heligon, Nga L Brown, William M Reichert, Bruce Klitzman

Abstract read
In one paragraph

Article in Acta biomaterialia, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 46 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Review
  6. Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. PLGA microsphere/PVA hydrogel coatings suppress the foreign body reaction for 6 months.Journal of controlled release : official journal of the Controlled Release Society · 2018
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Suzana G Vallejo-HeligonDepartment of Biomedical Engineering, Duke University, Durham, NC 27708-0281, United States.
Nga L BrownDepartment of Biomedical Engineering, Duke University, Durham, NC 27708-0281, United States; Kenan Plastic Surgery Research Labs, Duke University Medical Center, Durham, NC 27710, United States.
William M ReichertDepartment of Biomedical Engineering, Duke University, Durham, NC 27708-0281, United States. Electronic address: reichert@duke.edu.
Bruce KlitzmanDepartment of Biomedical Engineering, Duke University, Durham, NC 27708-0281, United States; Kenan Plastic Surgery Research Labs, Duke University Medical Center, Durham, NC 27710, United States.
Duke Medical Center · USDuke University · US

Funding

BIOSENSOR BIOCOMPATIBILITYR01DK054932 · NIDDK · DUKE UNIVERSITY · PI REICHERT, WILLIAM MONTGOMERY · 1999 to 2013
$4.2M
Biosensor BiocompatibilityR56DK054932 · NIDDK · DUKE UNIVERSITY · PI REICHERT, WILLIAM MONTGOMERY · 2008 to 2008
$258k
NIDDK NIH HHS DK 54932NIDDK NIH HHS R01 DK054932NIDDK NIH HHS R56 DK054932
6 · The paper itself

Abstract

Continuous glucose sensors offer the promise of tight glycemic control for insulin dependent diabetics; however, utilization of such systems has been hindered by issues of tissue compatibility. Here we report on the in vivo performance of implanted glucose sensors coated with Dexamethasone-loaded (Dex-loaded) porous coatings employed to mediate the tissue-sensor interface. Two animal studies were conducted to (1) characterize the tissue modifying effects of the porous Dex-loaded coatings deployed on sensor surrogate implants and (2) investigate the effects of the same coatings on the in vivo performance of Medtronic MiniMed SOF-SENSOR™ glucose sensors. The tissue response to implants was evaluated by quantifying macrophage infiltration, blood vessel formation, and collagen density around implants. Sensor function was assessed by measuring changes in sensor sensitivity and time lag, calculating the Mean Absolute Relative Difference (MARD) for each sensor treatment, and performing functional glucose challenge test at relevant time points. Implants treated with porous Dex-loaded coatings diminished inflammation and enhanced vascularization of the tissue surrounding the implants. Functional sensors with Dex-loaded porous coatings showed enhanced sensor sensitivity over a 21-day period when compared to controls. Enhanced sensor sensitivity was accompanied with an increase in sensor signal lag and MARD score. These results indicate that Dex-loaded porous coatings were able to elicit an attenuated tissue response, and that such tissue microenvironment could be conducive towards extending the performance window of glucose sensors in vivo. STATEMENT OF SIGNIFICANCE: In the present article, a coating to extend the functionality of implantable glucose sensors in vivo was developed. Our study showed that the delivery of an anti-inflammatory agent with the presentation of micro-sized topographical cues from coatings may lead to improved long-term glucose sensor function in vivo. We believe that improved function of sensors treated with the novel coatings was a result of the observed decreases in inflammatory cell density and increases in vessel density of the tissue adjacent to the devices. Furthermore, extending the in vivo functionality of implantable glucose sensors may lead to greater adoption of these devices by diabetic patients.

Indexed as

Coated Materials, BiocompatibleDexamethasoneElectrodes, ImplantedMaterials TestingPolyurethanesAnimalsBlood GlucoseMalePorosityRatsRats, Sprague-DawleyBlood GlucoseCoated Materials, BiocompatibleDexamethasonePolyurethanesAnimal modelsBiocompatibilityCoatingsForeign body responseGlucose sensorsInflammationPorosity

Identifiers

PMID26537203
PMCPMC4695308
OpenAlexW2206885398

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.