ArticleJournal of robotic surgery2015

R-LESS right colectomy with the single-site® robotic platform.

Konstantinos Konstantinidis, Savvas Hirides, Perikles Chrysoheris, Fotis Antonakopoulos, Petros Hirides

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Future of Minimally Invasive Colorectal Surgery.Clinics in colon and rectal surgery · 2016
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Konstantinos KonstantinidisGeneral, Laparoscopic and Robotic Surgery Clinic, Athens Medical Center, Distomou 3-5, Building D, 15125, Maroussi, Athens, Greece.
Savvas HiridesGeneral, Laparoscopic and Robotic Surgery Clinic, Athens Medical Center, Distomou 3-5, Building D, 15125, Maroussi, Athens, Greece. savashiridis@yahoo.com.
Perikles ChrysoherisGeneral, Laparoscopic and Robotic Surgery Clinic, Athens Medical Center, Distomou 3-5, Building D, 15125, Maroussi, Athens, Greece.
Fotis AntonakopoulosGeneral, Laparoscopic and Robotic Surgery Clinic, Athens Medical Center, Distomou 3-5, Building D, 15125, Maroussi, Athens, Greece.
Petros HiridesGeneral, Laparoscopic and Robotic Surgery Clinic, Athens Medical Center, Distomou 3-5, Building D, 15125, Maroussi, Athens, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUse of robotics has exemplified single-site procedures by restoring the correct hand-instrument alignment and providing stable, stereoscopic visual field. Technique was initially introduced by the manufacturers for cholecystectomy, but experienced teams quickly extended the indications to more complex procedures. We hereby present a case of a patient that underwent robotic right colectomy and omentectomy through the single-site(®) platform.

methodsA single-site procedure was offered to our 58-year-old male patient with carcinoma of the ascending colon and he gave written consent for it. The VESPA(®) single-site platform was used according to the standards of the manufacturing company. The single-site port(®) was placed at the umbilicus. Rest of setup and procedure steps were based on the multiport technique. An extended omentectomy accompanying the right colectomy has not previously reported to our knowledge. After sufficient mobilization specimen was exteriorized through the umbilicus, excised and the anastomosis was performed using linear staplers.

resultsConsole time was 164 min and total operation time was 221 min. Intraoperatively, there was no need for conversion, additional ports or blood transfusions. Total console time was 164 min. Lacking of wristed instruments and bipolar energy were regarded as serious limitations. No drains were used. Patient did not require ICU stay and had no postoperative complaints. He was given liquid diet on PO day #2 and he was discharged on PO day #4.

conclusionsRobotic single-site right colectomy is safe and feasible in selected cases. Experience from single-site robotic cholecystectomy is a useful basis to expand the indications to more complex procedures. Further development of the instruments and large number of cases may justify the indications for using this technique in the future.

Indexed as

ColectomyRobotic Surgical ProceduresColonic NeoplasmsGastrointestinal HemorrhageHumansMaleMiddle AgedRobotic SurgerySingle-incision colorectal surgerySingle-site platformSingle-site surgeryVESPA