Evidence map›Paper›PMID 26530969›Full record

ArticleJournal of robotic surgery2015

Modifications of transaxillary approach in endoscopic da Vinci-assisted thyroid and parathyroid gland surgery.

Basel Al Kadah, Micaela Piccoli, Barbara Mullineris, Giovanni Colli, Martin Janssen, Stephan Siemer, Bernhard Schick

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Observational
  2. Evolution Strategies in Transaxillary Robotic Thyroidectomy: Considerations on the First 449 Cases Performed.Journal of laparoendoscopic & advanced surgical techniques. Part A · 2019
    Article
  3. [Robotic Surgery - Who is The Boss?]Laryngo- rhino- otologie · 2018
    Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Basel Al KadahDepartment of Otorhinolaryngology, University Medical Center, Kirrberger Straße, 66421, Homburg, Saar, Germany. basel.al-kadah@uks.eu.
Micaela PiccoliDepartment of General Surgery, New Sant'Agostino Hospital, Modena, Italy.
Barbara MullinerisDepartment of General Surgery, New Sant'Agostino Hospital, Modena, Italy.
Giovanni ColliDepartment of General Surgery, New Sant'Agostino Hospital, Modena, Italy.
Martin JanssenDepartment of Urology, University Medical Center, Homburg, Saar, Germany.
Stephan SiemerDepartment of Urology, University Medical Center, Homburg, Saar, Germany.
Bernhard SchickDepartment of Otorhinolaryngology, University Medical Center, Kirrberger Straße, 66421, Homburg, Saar, Germany.
De Agostini (Italy) · ITSaarland University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Endoscopic surgery for treatment of thyroid and parathyroid pathologies is increasingly gaining attention. The da Vinci system has already been widely used in different fields of medicine and quite recently in thyroid and parathyroid surgery. Herein, we report about modifications of the transaxillary approach in endoscopic surgery of thyroid and parathyroid gland pathologies using the da Vinci system. 16 patients suffering from struma nodosa in 14 cases and parathyroid adenomas in two cases were treated using the da Vinci system at the ENT Department of Homburg/Saar University and in cooperation with the Department of General Surgery in New Sant'Agostino Hospital, Modena/Italy. Two different retractors, endoscopic preparation of the access and three different incision modalities were used. The endoscopic preparation of the access allowed us to have a better view during preparation and reduced surgical time compared to the use of a headlamp. To introduce the da Vinci instruments at the end of the access preparation, the skin incisions were over the axilla with one incision in eight patients, two incisions in four patients and three incisions in a further four patients. The two and three skin incisions modality allowed introduction of the da Vinci instruments without arm conflicts. The use of a new retractor (Modena retractor) compared to a self-developed retractor made it easier during the endoscopic preparation of the access and the reposition of the retractor. The scar was hidden in the axilla and independent of the incisions selected, the cosmetic findings were judged by the patients to be excellent. The neurovascular structures such as inferior laryngeal nerve, superior laryngeal nerve and vessels, as well as the different pathologies, were clearly 3D visualized in all 16 cases. No paralysis of the vocal cord was observed. All patients had a benign pathology in their histological examination. The endoscopic surgery of the thyroid and parathyroid gland can be performed using the da Vinci system and offers an excellent, intra-operative, 3D visualization of the neurovascular structures. The new incision modalities, use of a new retractor, and endoscopic preparation of the access made the surgery easier and safer using the transaxillary access to the thyroid and parathyroid glands. The modified skin incisions allowed an improved movement of the da Vinci arms during operation.

Indexed as

AdolescentAdultAxillaEndoscopyFemaleHumansMaleMiddle AgedParathyroid GlandsRobotic Surgical ProceduresThyroid GlandYoung Adultda Vinci systemModena retractorModified transaxial skin incisionParathyroid glandStereoscopic viewThyroid gland

Identifiers

PMID26530969
OpenAlexW2005501301

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.