ArticleJournal of cardiothoracic surgery2015
Automated fastener versus manually tied knots in minimally invasive mitral valve repair: impact on operation time and short- term results.
Article in Journal of cardiothoracic surgery, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 39 citations in OpenAlex.
- Management strategies for loosened knots during cardiac surgery.Journal of cardiothoracic surgery · 2026Article
- Article
- Comparison of outcomes post Cor-Knot versus Manual tying in valve surgery: our 8-year analysis of over 1000 patients.Journal of cardiothoracic surgery · 2025Article
- Acute Clinical Adverse Outcomes Associated With the Cor-Knot.Annals of thoracic surgery short reports · 2025Article
- Automated titanium fastener vs. hand-tied knots for prosthesis fixation in infective endocarditis.Frontiers in cardiovascular medicine · 2024Article
- Efficacy of automated fasteners versus hand-tied knots in cardiac surgery: a systematic review and meta-analysis.EXCLI journal · 2024Review
- A qualitative improvement program for minimally invasive mitral surgery: technical advancements ameliorate outcome and operative times.Interdisciplinary cardiovascular and thoracic surgery · 2023Article
- Aortic Root Dissection Due to an Automated Fastener Device.Texas Heart Institute journal · 2022Article
- Safety and Effectiveness Outcomes of a Novel Automated Titanium Suture Fastener Device Applied for Heart Valve Surgery in an Ovine Model.Frontiers in cardiovascular medicine · 2022Article
- Incidence of valvular regurgitation and leaflet perforation by using automated titanium fasteners (CORKNOT®) in heart valve repair or replacement: less usual than reported.Journal of cardiothoracic surgery · 2021Article
- A Rare Etiology for Bioprosthetic Aortic Valve Regurgitation.CASE (Philadelphia, Pa.) · 2020Article
- Inaugural experience and early results of minimally invasive approach in cardiac surgery in Auvergne region, France.Journal of cardiovascular and thoracic research · 2020Article
- Use of an automated knot fastener shortens operative times in minimally invasive mitral valve repair.Annals of the Royal College of Surgeons of England · 2019Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis study compares the influence of two different annuloplasty attachment suture applications, namely the use of an automated fastener versus manually tied knots using a traditional knot pusher, on total operation time, on cardiopulmonary-bypass time and on cross-clamp time, and on short-term outcome.
methodsSixty patients underwent isolated minimally invasive mitral valve repair in Carpentier Type-II mitral disease with implantation of an annuloplasty ring in combination with correction of the prolapsing leaflet using artificial chords. The first 30 patients after implementation of a novel automated fastener were compared with the last 30 patients corrected with a traditional knot pusher. No significant differences with regard to demographic data (age, gender, NYHA class, ejection fraction, BMI, cardiovascular risk factors) between the two groups were found. All patients received isolated mitral valve repair in the first run. Bretschneider HTK was used for cardioplegic cardiac arrest in all patients.
resultsTransesophageal and transthoracic echocardiography at the end of operation and at discharge revealed no (n = 25), trace (n = 28) or mild (n = 7) residual regurgitation with no evidence of ring dehiscence and without any significant clinical differences between the groups. Cross-clamp, cardiopulmonary-bypass and total- operation time were significantly reduced in the automated fastener group compared to the group using a traditional knot pusher (87.1 ± 17.9 vs. 101.3 ± 17.8; p < 0.01, 138.1 ± 25.6 vs. 152.7 ± 24.9; p < 0.05, and 203.9 ± 31.02 vs. 223.8 ± 29.01; p < 0.01, respectively).
conclusionOur short-term results indicate a safe, reliable and fast application of the novel automated fastener device in combination with significant time savings in cardioplegic arrest and cardiopulmonary bypass.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.