In one paragraph

Trial report in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Ji-Hyun ChinDepartment of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Wook-Jong KimDepartment of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Jeong-Hyun ChoiDepartment of Anesthesiology and Pain Medicine, School of Medicine, Kyung Hee University, Seoul, Korea.
Yun A HanDepartment of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Seon-Ok KimDepartment of Clinical Epidemiology and Biostatistics, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Woo-Jong ChoiDepartment of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Asan Medical Center · KRKyung Hee University · KRUlsan College · KRUniversity of Ulsan · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe FloTrac/Vigileo™ system does not thoroughly reflect variable arterial tones, due to a lack of external calibration. The ability of this system to measure stroke volume and track its changes after fluid administration has not been fully evaluated in patients with the high systemic vascular resistance that can develop during laparoscopic surgery.

methodsIn 42 patients undergoing laparoscopic prostatectomy, the stroke volume derived by the third-generation FloTrac/Vigileo™ system (SV-Vigileo), the stroke volume measured using transesophageal echocardiography (SV-TEE) as a reference method, and total systemic vascular resistance were evaluated before and after 500 ml fluid administration during pneumoperitoneum combined with the Trendelenburg position.

resultsTotal systemic vascular resistance was 2159.4 ± 523.5 dyn·s/cm5 before fluid administration. The SV-Vigileo was significantly higher than the SV-TEE both before (68.8 ± 15.9 vs. 57.0 ± 11.0 ml, P < 0.001) and after (73.0 ± 14.8 vs. 64.9 ± 12.2 ml, P = 0.003) fluid administration. During pneumoperitoneum combined with the Trendelenburg position, Bland-Altman analysis for repeated measures showed a 53.8% of percentage error between the SV-Vigileo and the SV-TEE. Four-quadrant plot (69.2% of a concordance rate) and polar plot analysis (20.6° of a mean polar angle, 16.4° of the SD of a polar angle, and ±51.5° of a radial sector containing 95% of the data points) did not indicate a good trending ability of the FloTrac/Vigileo™ system.

conclusionsThe third-generation FloTrac/Vigileo™ system may not be useful in patients undergoing laparoscopic surgery, based on unreliable performance in measuring the stroke volume and in tracking changes in the stroke volume after fluid administration during pneumoperitoneum combined with the Trendelenburg position.

Indexed as

PneumoperitoneumVascular ResistanceAgedEchocardiography, TransesophagealFemaleHumansLaparoscopyMaleMiddle AgedVideo-Assisted Surgery

Identifiers

PMID26529592
PMCPMC4631474
OpenAlexW2137533118

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.