Reliability and failure modes of narrow implant systems.

Ronaldo Hirata, Estevam A Bonfante, Rodolfo B Anchieta, Lucas S Machado, Gileade Freitas, Vinicius P Fardin, Nick Tovar, Paulo G Coelho

Open access · bronzeAbstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Ronaldo HirataDepartment of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
Estevam A BonfanteDepartment of Prosthodontics, Bauru College of Dentistry, University of São Paulo, Alameda Otávio Pinheiro Brisola 9-75, Bauru, SP, 17.012-901, Brazil. estevamab@gmail.com.
Rodolfo B AnchietaDepartment of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
Lucas S MachadoDepartment of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
Gileade FreitasDepartment of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
Vinicius P FardinDepartment of Prosthodontics, Bauru College of Dentistry, University of São Paulo, Alameda Otávio Pinheiro Brisola 9-75, Bauru, SP, 17.012-901, Brazil.
Nick TovarDepartment of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
Paulo G CoelhoDepartment of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
New York University · USUniversidade de São Paulo · BRUniversidade Estadual Paulista (Unesp) · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesNarrow implants are indicated in areas of limited bone width or when grafting is nonviable. However, the reduction of implant diameter may compromise their performance. This study evaluated the reliability of several narrow implant systems under fatigue, after restored with single-unit crowns. MATERIALS AND

methodsNarrow implant systems were divided (n = 18 each), as follows: Astra (ASC); BioHorizons (BSC); Straumann Roxolid (SNC), Intra-Lock (IMC), and Intra-Lock one-piece abutment (ILO). Maxillary central incisor crowns were cemented and subjected to step-stress accelerated life testing in water. Use level probability Weibull curves and reliability for a mission of 100,000 cycles at 130- and 180-N loads (90 % two-sided confidence intervals) were calculated. Scanning electron microscopy was used for fractography.

resultsReliability for 100,000 cycles at 130 N was ∼99 % in group ASC, ∼99 % in BSC, ∼96 % in SNC, ∼99 % in IMC, and ∼100 % in ILO. At 180 N, reliability of ∼34 % resulted for the ASC group, ∼91 % for BSC, ∼53 % for SNC, ∼70 % for IMC, and ∼99 % for ILO. Abutment screw fracture was the main failure mode for all groups.

conclusionsReliability was not different between systems for 100,000 cycles at the 130-N load. A significant decrease was observed at the 180-N load for ASC, SNC, and IMC, whereas it was maintained for BSC and ILO. CLINICAL RELEVANCE: The investigated narrow implants presented mechanical performance under fatigue that suggests their safe use as single crowns in the anterior region.

Indexed as

Dental ImplantsCrownsDental AbutmentsDental Prosthesis DesignDental Prosthesis, Implant-SupportedDental Restoration FailureDental Stress AnalysisHumansMaterials TestingMicroscopy, Electron, ScanningReproducibility of ResultsSurface PropertiesTitaniumDental ImplantsTitaniumBiomechanicsDental implantsFatigueReliabilityWeibull

Identifiers

PMID26526325
OpenAlexW1917849842

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.